Setting level 2: external torque limit – Yaskawa FSP Amplifier User Manual
Page 77

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-10
Setting Level 2: External Torque Limit
A contact input signal is used to enable the torque (current) limits 
previously set in parameters. Torque limits can be set separately for 
forward and reverse rotation. 
Torque limit
Pn402
Rotation
speed
Torque
Torque
Torque
Torque
Rotation
speed
Rotation
speed
Rotation
speed
Torque limit
Pn402 or Pn404
(limited by whichever
is smaller)
Torque limit
Pn403
Torque limit
Pn403 or Pn405
(limited by whichever
is smaller)
Reverse
rotation
Forward
rotation
/P- CL
/ N - CL
CN1 -45
CN1 -46
FSP Amplifier
Ö
Input /P-CL CN1-45
Forward External Torque Limit 
Input 
Speed, Torque, and Position 
Control 
Ö
Output /N-CL CN1-46
Reverse External Torque Limit 
Input 
Speed, Torque, and Position 
Control 
This is the external torque (current) limit input for forward and reverse 
rotation. 
Check input signal allocation status when using this function (see 5.3.3 
Input Circuit Signal Allocation). Default settings are given in the table 
below. 
Signal Signal
Status
Comments
Description
CN1-45 at low level when ON
Use forward torque limit.
Limit: Pn404
/P-CL
CN1-45 at high level when OFF
Do not use forward torque 
limit. Normal operation. 
—
CN1-46 at low level when ON
Use reverse torque limit.
Limit: Pn405
/N-CL
CN1-46 at high level when OFF
Do not use reverse torque 
limit. Normal operation. 
—