2.1. Servo Amplifiers

The FSP Amplifier servo amplifiers are base-mounted. Incorrect installation will
cause problems. Follow the installation instructions below.

2.1.1. Storage Conditions

Store the servo amplifier within the following temperature range, as long as
it is stored with the power cable disconnected.
Temperature range: -20 to 85°C

2.1.2. Installation Site

The following precautions apply to the installation site.

Situation Installation

Precaution

Installation in a Control Panel

Design the control panel size, unit layout, and cooling
method so the temperature around the servo amplifier does
not exceed 55°C.

Installation near a Heating Unit

Minimize heat radiated from the heating unit as well as any
temperature rise caused by natural convection so the
temperature around the servo amplifier does not exceed
55°C.

Installation near a Source of Vibration

Install a vibration isolator beneath the servo amplifier to
avoid subjecting it to vibration.

Installation at a Site Exposed to
Corrosive Gas

Corrosive gas does not have an immediate effect on the
servo amplifier, but will eventually cause electronic
components and contactor-related devices to malfunction.
Take appropriate action to avoid corrosive gas.

Other Situations

Do not install the servo amplifier in hot and humid locations
or locations subject to excessive dust or iron powder in the
air.