Acceleration units – Yaskawa FSP Amplifier User Manual
Page 160

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-93
65535
N
tof
Integerpar
HB
HighBit
=
=
65536
•
−
=
HB
N
LowBits
, where N = required value.
Example:
A rotary motion system uses a motor with a 17-bit encoder. The user wants
to program the system in speed units of rpm:
17-bit encoder produces 131072[counts] per revolution.
U = 131072
1[minute]=60000[ms]
T = 60000
1[rpm] =
[
]
r
denominato
ratio
units
Speed
numerator
ratio
units
Speed
]
[
60000
]
[
131072
]
[
]
[
=
=
ms
counts
ms
T
counts
U
First option: Second option:
Both options are equivalent.
5.9.1.4. Acceleration Units
Use the following parameters to convert acceleration units from [encoder
counts/(10 msec)
2
] to [user acceleration units]:
Parameter Setting
Default
Setting
Signal
Pn2B8
1 to 65535
1
Acceleration units ratio numerator
Pn2B9
0 to 16383
0
Acceleration units ratio numerator (high bits)
Pn2BA
1 to 65535
1
Acceleration units ratio denominator
Pn2BB
0 to 16383
0
Acceleration units ratio denominator (high bits)
It is possible to reduce the
fraction so that both the
numerator and denominator are
smaller than 65536:
131072 / 60000 = 32768 /15000
Æ Reduction
Pn2B4 = 32768
Pn2B5 = 0
Pn2B6 = 15000
Pn2B7 = 0
Without reduction of the fraction:
High Bits = HB = Integer part of
N/65536 = Integer part of 131072
/ 65536 = 2
Low Bits = N – HB*65536 =
131072 – 2 * 65536 = 0
Pn2B4 = 0
Pn2B5 = 2
Pn2B6 = 60000
Pn2B7 = 0