Chapter 8: Ratings, Specifications and Dimensional Drawings
8-9
8.5. Three-phase 400 V FSP Amplifier and Motors Combinations
FSP Amplifier Model FSP-
05D*
10D*
15D*
20D*
30D*
50D*
Model SGMGH-
05D
09D
13D 20D
30D
44D
Capacity
(kW)
0.45 0.85 1.30 1.80 2.90 4.40
Appli
cab
le
Serv
om
otor
Motor Speed (rpm)
Rated 1500, maximum 3000
Applicable Encoder
YASKAWA serial or incremental A quad B or absolute encoder.
DIFFERENT incremental A quad B encoders
Continuous Output Current
A
rms
1.9 3.5 5.4 8.4 11.9 16.5
Maximum Output Current A
rms
5.5 8.5 14 20 28 40.5
SGM
G
H Series
(Yask
aw
a or
co
mpat
ibl
e)
Allowable Regenerative
Frequency* (times / min)
42 15 10 12 8 11
Model SGMSH-
—
10D
15D 30D
30D
40D 50D
Capacity (KW)
—
1.00
1.50 3.00 3.00
4.00
5.00
Appli
cab
le
Serv
om
otor
Motor Speed (rpm)
Rated 3000, maximum 5000
Applicable Encoder
YASKAWA serial or incremental A quad B or absolute encoder.
DIFFERENT incremental A quad B encoders
Continuous Output Current
A
rms
— 2.8 4.7 6.2 8.9
12.5
13.8
Maximum Output Current A
rms
— 8.5 14 19.5
28
38
42
SGM
SH Serie
s
(Yask
aw
a or
co
mpat
ibl
e)
Allowable Regenerative
Frequency* (times / min)
— 47 31 48 20
29
22
Model SGMUH-
—
10D
15D
—
30D
—
Capacity (KW)
—
1.00
1.50
—
3.00
—
Appli
cab
le
Servo
m
otor
Motor Speed (rpm)
Rated 6000, maximum 6000
Applicable Encoder
YASKAWA serial or incremental A quad B or absolute encoder.
DIFFERENT incremental A quad B encoders
Continuous Output Current A
rms
— 2.7 4.1 — 8.1
—
Maximum Output Current A
rms
— 8.5 14 — 28
—
SGM
UH Series
(Yask
aw
a or
co
mpat
ibl
e)
Allowable Regenerative
Frequency* (times / min)
— 27 19 — 13
—
* Allowable regenerative frequency is the allowable frequency in the motor while accelerating and decelerating
through a 0 Æ maximum motor speed
Æ 0 (r / min) cycle.
Note: Refer to Chapter 5.6 Selecting a Regenerative Resistor for more details on allowable regenerative energy