Allocating other input signals – Yaskawa FSP Amplifier User Manual
Page 116

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-49
Allocating Other Input Signals
Input signal allocation can be changed as shown below.
Input Signal
Parameter
Description
Name
Applicable
Logic
Number Setting
0
Inputs the specified signal from SI0 (CN1-40).
1
Inputs the specified signal from SI1 (CN1-41).
2
Inputs the specified signal from SI2 (CN1-42).
3
Inputs the specified signal from SI3 (CN1-43).
4
Inputs the specified signal from SI4 (CN1-44).
5
Inputs the specified signal from SI5 (CN1-45).
6
Inputs the specified signal from SI6 (CN1-46).
7
Sets the specified signal to always enabled.
8
Sets the specified signal to always disabled.
9
Inputs the specified inverse signal from SI0 (CN1-40).
A
Inputs the specified inverse signal from SI1 (CN1-41).
B
Inputs the specified inverse signal from SI2 (CN1-42).
C
Inputs the specified inverse signal from SI3 (CN1-43).
D
Inputs the specified inverse signal from SI4 (CN1-44).
E
Inputs the specified inverse signal from SI5 (CN1-45).
Proportional
Control
Reference
(/P-CON)
ON
(low level)
Pn50A.2
F
Inputs the specified inverse signal from SI6 (CN1-46).
Forward Run
Prohibit
(P-OT)
Pn50A.3
Reverse Run
Prohibit
(N-OT)
OFF
(high
level)
Pn50B.0
Alarm Reset
(/ARM-RST)
Pn50B.1
Forward
Current Limit
(/P-CL)
Pn50B.2
Reverse
Current Limit
(/N-CL)
ON
(low
level)
Pn50B.3
Contact Input
Speed Control
Selection
(/SPD-D)
Pn50C.0
Contact Input
Speed Control
Selection
(/SPD-A)
Pn50C.1
Contact Input
Speed Control
Selection
(/SPD-B)
—
Pn50C.2
Control Mode
Selection
(/C-SEL)
Pn50C.3
Zero Clamp
(/ZCLAMP)
Pn50D.0
Reference
Pulse Inhibit
(/INHIBIT)
ON
(low
level)
Pn50D.1
0 to F
Same as above.*
Note:
*Same as above” means that input signals and terminals SI0 to SI6 are enabled or disabled through
parameter settings 0 to 8.