Troubleshooting, Troubleshooting problems with alarm displays, A.02: parameter breakdown – Yaskawa FSP Amplifier User Manual
Page 270

FSP Amplifier User’s Manual
Chapter 9: Inspection, Maintenance, and Troubleshooting
9-5
9.2. Troubleshooting
This section describes causes and remedies for problems, which generate an
alarm display, and for problems, which result in no alarm display.
9.2.1. Troubleshooting Problems with Alarm Displays
Problems that occur in the servo drives are displayed on the panel operator
as “A.”. Refer to the following sections to identify the cause of an
alarm and the action to be taken.
Contact YEA if the problem has not been solved after following the
described procedures.
Note: “A.- -: Normal Operation”, is not an alarm.
A.02: Parameter Breakdown
Display and Outputs
Alarm Outputs
Alarm Code Output
ALO1 ALO2
ALO3
ALM Output
OFF OFF
OFF
OFF
Note: OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Cause of the Problem
Solution
A
Power turned OFF during parameter
writes. Alarm occurred at next
power ON.
•
Initialize parameters using
Fn005 then re-enter settings.
•
Replace the servo amplifier.
B
Circuit board (1PWB) defective.
Replace the servo amplifier.
At Power ON
A, B