beautypg.com

Troubleshooting, Troubleshooting problems with alarm displays, A.02: parameter breakdown – Yaskawa FSP Amplifier User Manual

Page 270

background image

FSP Amplifier User’s Manual

Chapter 9: Inspection, Maintenance, and Troubleshooting

9-5

9.2. Troubleshooting

This section describes causes and remedies for problems, which generate an
alarm display, and for problems, which result in no alarm display.

9.2.1. Troubleshooting Problems with Alarm Displays

Problems that occur in the servo drives are displayed on the panel operator
as “A.††”. Refer to the following sections to identify the cause of an
alarm and the action to be taken.
Contact YEA if the problem has not been solved after following the
described procedures.

Note: “A.- -: Normal Operation”, is not an alarm.

„

A.02: Parameter Breakdown

Display and Outputs

Alarm Outputs

Alarm Code Output

ALO1 ALO2

ALO3

ALM Output

OFF OFF

OFF

OFF

Note: OFF: Output transistor is OFF (alarm state).

Status and Remedy for Alarm

Cause of the Problem

Solution

A

Power turned OFF during parameter
writes. Alarm occurred at next
power ON.

Initialize parameters using
Fn005 then re-enter settings.

Replace the servo amplifier.

B

Circuit board (1PWB) defective.

Replace the servo amplifier.

At Power ON

A, B