The following warning codes are output in 3 bits – Yaskawa FSP Amplifier User Manual
Page 137

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-70
Parameter Signal
Setting
Control
Mode
Pn50F
Output Signal Selections 2
Default Setting: 0000
Speed, Torque,
Position Control, and
Programming
Pn50F.3 is used to allocate the /WARN output signals above.
Output Terminal (CN1-)
Pn50F.3 State
*1 *2
0 —
—
1 25 26
2 27 28
3 29 30
Note:
*1 and *2 are output terminals allocated with parameter Pn 510.0.
Multiple signals allocated to the same output terminal follow Boolean OR logic. In order to use the /WARN
output signal alone, set other output signals to a value other than the one allocated to the /WARN signal. See
5.3.4 Output Circuit Signal Allocation.
/WARN
Warning
output signal
SO1 (CN1-25, 26)
SO2 (CN1-27, 28)
SO3 (CN1-29, 30)
Pn50F.3
1
2
3
Output terminals
The following parameter is used to output warning details with an alarm
code.
Parameter Signal
Setting
Control
Mode
Pn001.3
Warning Code Output
Selection
Default Setting: 0
Speed, Torque,
Position Control,
and Programming
Pn001.3 Setting
Result
0
Outputs alarm codes only for alarm codes ALO1,
ALO2 and ALO3.
1
Outputs both alarm and warning codes for alarm
codes ALO1, ALO2 and ALO3 and outputs an
alarm code when an alarm occurs.
The following warning codes are output in 3 bits.
Warning Code Output
Warning
Indication
ALO1 ALO2 ALO3
Warning Description
A.91
ON signal
(low level)
OFF signal
(high level)
OFF signal
(high level)
Overload
A.92
OFF signal
(high level)
ON signal
(low level)
OFF signal
(high level)
Regenerative overload