Torque limiting by analog voltage reference, Using torque limiting by analog voltage reference – Yaskawa FSP Amplifier User Manual
Page 109

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-42
5.2.9. Torque Limiting by Analog Voltage Reference
Torque limiting by analog voltage reference limits the torque by assigning
a torque analog voltage to the T-REF terminal (CN1-9 and 10). It cannot be
used for torque control because the torque reference input terminal T-REF
is used as an input terminal.
The torque is limited at the forward run side when the P-CL signal turns
ON and at the reverse run side when the N-CL signal turns ON.
T-REF Pn400
Totque limit value
Speed reference
V-REF Pn300
_
+
Speed feedback
gain
Speed loop
(Pn100)
Integration
(Pn101)
+
+
Pn403
Torque limit
Torque
reference
Torque limit
Pn402
Using Torque Limiting by Analog Voltage Reference
To use this function, set the following parameter to 3:
Parameter Signal
Setting
Control
Mode
Pn002.0
Speed Control Option
(T-REF Terminal Allocation)
Default Setting: 0
Speed Control
This parameter can be used to enable torque limiting by analog voltage
reference.
Pn002.0 Setting
T-REF Function
0 None.
1
T-REF terminal used for external torque limit input.
2
T-REF terminal used for torque feed-forward input.
3
T-REF terminal used for external torque limit input when P-CL
and N-CL are valid.
This function cannot be used with the torque feed-forward function
described in 5.2.8 Torque Feed-Forward Function.