FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-84
5.7.4. Absolute Encoder Reception Sequence
This section describes the sequence in which the servo amplifier receives 
data from the absolute encoder and transmits it to the host device. Be sure 
you understand this section when designing the host device. 
Outline of Absolute Signals
The absolute encoder’s outputs are PAO, PBO, PCO, and PSO signals as 
shown below. 
FSP Amplifier
Signal Status
Contents
Initial State
Serial data 
Initial incremental pulse 
PAO
Normal State
Incremental pulse
Initial State
Initial incremental pulse
PBO
Incremental pulse
PCO
Home position pulse
PSO
Normal State
Rotation count serial data
Contents of Absolute Data
• Serial data: Indicates how many turns the motor shaft has made from
the reference position (position specified at setup).
• Initial incremental pulse: Outputs pulses at the same pulse rate as when
the motor shaft rotates from the home position to the current position at 
approximately 2500rpm (for 16 bits when the dividing pulse is at the 
default setting). 