D.5. auxiliary functions, D.6. monitor modes, D-14 – Yaskawa FSP Amplifier User Manual
Page 359: The following list shows monitor modes available

FSP Amplifier User’s Manual
Appendix D: List of Parameters
D-14
D.5. Auxiliary Functions
The following list shows the available auxiliary functions.
Parameter Function
Fn000
Alarm trace-back data display
Fn001
Rigidity setting during online auto-tuning
Fn002
JOG mode operation
Fn003
Zero-point search mode
Fn004
(Reserved function; do not change)
Fn005
Parameter settings initialization
Fn006
Alarm trace-back data clear
Fn007
Writing to EEPROM the inertia ratio data obtained from online auto-tuning
Fn008
Absolute encoder multi-turn reset and encoder alarm reset.
Fn009
Automatic tuning of analog (speed, torque) reference offset
Fn00A
Manual adjustment of speed reference offset
Fn00B
Manual adjustment of torque reference offset
Fn00C
Manual zero-adjustment of analog monitor output
Fn00D
Manual gain-adjustment of analog monitor output
Fn00E
Automatic offset-adjustment of motor current detection signal
Fn00F
Manual offset-adjustment of motor current detection signal
Fn010
Password setting (protects from parameter & some function changes)
Fn011
Motor models display
Fn012
Software version display
Fn013
Set absolute encoder multi-turn limit
D.6. Monitor Modes
The following list shows monitor modes available
Parameter
Content of Display
Unit
Remarks
Un000
Motor speed
rpm
Measured motor speed.
Un001
Input speed reference
rpm
Commanded motor speed.
Un002
Internal torque reference
% of rated
torque
Present torque applied to motor.
Un003 Rotation
angle
1
pulses
Number of pulses from the origin
(Used for commutation; not generally
useful to user).
Un004 Rotation
angle
2
degrees
Electrical angle from the origin
(Used for commutation; not generally
useful to user).
Un005
Input signal monitor
—
On/Off status of inputs.
Un006
Output signal monitor
—
On/Off status of outputs.
Un007
Input reference pulse speed
rpm
—
Un008*
Error counter value
reference unit
Error between commanded position and
actual motor position.
Un009
Accumulated load rate
% of rated
torque
RMS torque over the last 10 seconds.
Un00A
Regenerative load rate
% of max.
regenerative
power
Average power dissipated by the
regenerative resistor over the last 10
seconds.
Un00B
Power consumed by DB
resistor
% of max
Average power consumed by the dynamic
braking resistor over the last 10 seconds.
This is equivalent to the value for the
processable power when dynamic brake is
applied at 100%.
Un00C
Input reference pulse
counter
Number of
pulses (in hex)
Number of command pulses received by
the amplifier.
Un00D
Feedback pulse counter
Number of
pulses (in hex)
Number of feedback pulses received by
the amplifier. (See notes 2 and 4 below)
*Not used in serial communication command.