Output circuit signal allocation, Output signal selection default settings – Yaskawa FSP Amplifier User Manual
Page 117

FSP Amplifier User’s Manual
Chapter 5: Parameter Settings and Functions
5-50
5.3.4. Output Circuit Signal Allocation
Output Signal Allocation
Output signal functions can be allocated to the sequence signal output
circuits shown below.
Default Setting
CN1 Connector
Terminal
Numbers
Output
Terminal
Name
Symbol Name
Comments
25
/V-CMP+
(/COIN+)
26 (SG)
SO1
/V-CMP–
(/COIN–)
Speed coincidence
detection
(positioning
completed)
The signal output
will vary depending
on the control mode.
27 /TGON+
28 (SG)
SO2
/TGON–
Rotation detection
—
29 /S-RDY+
30 (SG)
SO3
/S-RDY–
Servo ready
—
Output Signal Selection Default Settings
The output signal selection parameters and their default settings are shown
below.
Parameter Signal
Setting
Control
Mode
Pn50E
Output Signal Selections 1
Default Setting: 3211
Speed, Torque, Position
Control, and
Programming
Pn50F
Output Signal Selections 2
Default Setting: 0000
Speed, Torque, Position
Control, and
Programming
Pn510
Output Signal Selections 3
Default Setting: 0000
Speed, Torque, Position
Control, and
Programming
Select the CN1 connector terminals that will output the signals.
Output
signal
SO1 (CN1-25, 26)
SO2 (CN1-27, 28)
SO3 (CN1-29, 30)
Pn50E. to Pn510.