Important – Yaskawa FSP Amplifier User Manual
Page 199

FSP Amplifier User’s Manual
Chapter 7: Using the Panel Operator
7-8
Function Selection Parameters
Function Selection Parameter Types
The following table shows the parameters for selecting servo amplifier
functions.
Category
Parameter
Number
Name
Default
Setting
Important
Note
Pn000
Function Selection Basic Switches
0000
(See 1)
Pn001
Function Selection Application
Switches 1
0000 (See
1)
Pn002
Function Selection Application
Switches 2
0000 (See
1)
Function Selection
Parameters
Pn003
Function Selection Application
Switches 3
0002 —
Gain-related Parameters
Pn110
Online Auto-tuning Switches
0010
(See 2)
Position Control
related Parameter
Pn200
Position Control Reference
Selection Switches
0000 (See
1)
Pn50A
Input Signal Selections 1
2100
(See 1)
Pn50B
Input Signal Selections 2
6543
(See 1)
Pn50C
Input Signal Selections 3
8888
(See 1)
Pn50D
Input Signal Selections 4
8888
(See 1)
Pn50E
Output Signal Selections 1
3211
(See 1)
Pn50F
Output Signal Selections 2
0000
(See 1)
Sequence-related
Parameters
Pn510
Output Signal Selections 3
0000
(See 1)
IMPORTANT
1. After changing these parameters, turn OFF the main circuit and control power supplies and then
turn them ON again to enable the new settings.
2. Changing bits Pn10B.1 and Pn110.0 require the same sequence described in note 1 (above).