round-trip min/avg/max = 10/76/180 ms

Example for configuring a remote CCC connection

Network requirements

As shown in

Figure 50

, the CEs are connected to the PEs through GigabitEthernet interfaces.

Create a remote CCC connection between CE 1 and CE 2.
The main steps for configuring a CCC remote connection are:

1.

Create a remote CCC connection on the PEs. No static LSP is required on the PEs.

2.

Enable MPLS L2VPN on the PEs. You do not need to enable MPLS L2VPN on the P router.

3.

Configure two static LSPs on the P router for packets to be transferred in both directions.

Figure 50 Network diagram

Device Interface IP

address

Device

Interface

IP address

CE 1

GE4/1/1

100.1.1.1/24

P

Loop0

10.0.0.2/32

PE 1

Loop0

10.0.0.1/32

GE4/1/1 10.2.2.2/24

GE4/1/2

10.1.1.1/24

GE4/1/2 10.1.1.2/24

CE 2

GE4/1/1

100.1.1.2/24

PE 2

Loop0

10.0.0.3/32

GE4/1/1 10.2.2.1/24

Configuration procedure

1.

Configure CE 1.

system-view

[Sysname] sysname CE1

[CE1] interface GigabitEthernet 4/1/1

[CE1-GigabitEthernet4/1/1] ip address 100.1.1.1 24

2.

Configure PE 1.
# Configure the LSR ID and enable MPLS globally.

system-view

[Sysname] sysname PE1

[PE1] interface loopback 0

[PE1-LoopBack0] ip address 10.0.0.1 32

[PE1-LoopBack0] quit

[PE1] mpls lsr-id 10.0.0.1

[PE1] mpls

[PE1-mpls] quit