Mpls te using cr-ldp configuration example, Network requirements – H3C Technologies H3C SR8800 User Manual
Page 120

109
# Configure Router A.
[RouterA] interface GigabitEthernet 3/1/1
[RouterA-GigabitEthernet3/1/1] ip address 12.12.12.1 24
[RouterA-GigabitEthernet3/1/1] quit
# Configure Router B.
[RouterB] interface GigabitEthernet 3/1/1
[RouterB-GigabitEthernet3/1/1] ip address 12.12.12.2 24
4.
Configure the MPLS TE tunnel
# Configure an RSVP-TE tunnel between Router A and Router B.
[RouterA] interface tunnel 1
[RouterA-Tunnel1] ip address 10.10.10.1 24
[RouterA-Tunnel1] tunnel-protocol mpls te
[RouterA-Tunnel1] destination 2.2.2.2
[RouterA-Tunnel1] mpls te tunnel-id 10
[RouterA-Tunnel1] mpls te signal-protocol rsvp-te
[RouterA-Tunnel1] mpls te commit
[RouterA-Tunnel1] return
5.
Verify the configuration
Display the detailed information of the BFD session between Router A and Router B.
Total Session Num: 1 Init Mode: Active
Session Working Under Ctrl Mode:
Local Discr: 19 Remote Discr: 18
Source IP: 12.12.12.1 Destination IP: 12.12.12.2
Session State: Up Interface: GigabitEthernet3/1/1
Min Trans Inter: 400ms Act Trans Inter: 400ms
Min Recv Inter: 400ms Act Detect Inter: 2000ms
Running Up for: 00:00:01 Auth mode: None
Connect Type: Direct Board Num: 6
Protocol: RSVP
Diag Info: No Diagnostic
MPLS TE using CR-LDP configuration example
Network requirements
Router A, Router B, Router C and Router D are running OSPF and all of them are in area 0.
Use CR-LDP to create a TE tunnel from Router A to Router D, ensuring that the maximum bandwidth of
each link that the tunnel traverses is 10000 kbps and the maximum reservable bandwidth is 5000 kbps.