User Manual - Rev H

California Instruments

Avionics Software

95

1.7

Steady State Frequency (see Designer Notes)

360 to 800 Hz

Requirement fulfilled in 1.1 and 1.2

1.8

Frequency Modulation

Per Figure 2

2 mins each test (360, 800Hz nominal)

HVAC-18

2.0

Normal AC Transients

2.1

Voltage Transients

50ms Dropouts

800Hz and 360Hz

HVAC-21-1

2.1

Voltage Transients

Voltage Surge/Sag

3 times each, 800Hz and 360Hz

HVAC-21-2

2.1

Voltage Transients

Per Table B.2.1.1.1

2 times each

HVAC-21-3

2.2

Voltage Spikes

Per Figure 10

Requires additional equipment

2.3

Frequency Transients

2.3.1

Maximum Ramp Rate

100Hz/s up, 200Hz/s down

3 times each, 360Hz nominal

HVAC-23

3.0

Abnormal AC Steady State

3.1

Individual Phase Voltage

190.0 to 268.0 Volts RMS

Single Phase Unit Test

HVAC-31-1

3.1

Individual Phase Voltage

190.0 to 268.0 Volts RMS

Three Phase Unit Test

HVAC-31-2

3.2

Average of Three-Phase Voltages

193.0 to 265.0 Volts RMS

5 mins each test

HVAC-32

3.3

Abnormal Steady State Frequency (see Designer Notes)

360 to 800 Hz

Requirement fulfilled in 1.7

4.0

Abnormal AC Transients

4.1

Voltage Transients

Per Figure 5A

Apply each transient 3x with 10s interval

HVAC-41

4.2

Frequency Transients

4.2.1

Maximum Ramp Rate

100Hz/s up, 200Hz/s down

Test procedure TBD

4.2.2

Transients Outside of Steady State Range

Per Figure 6

Test procedure TBD

4.3

DC Content

Per Figure 11

Test procedure TBD

SUPP

Supplementary Transient Test Requirements

Tests 1-7, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-1

SUPP

Supplementary Transient Test Requirements

Tests 8-14, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-2

SUPP

Supplementary Transient Test Requirements

Tests 15-20, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-3

SUPP

Supplementary Transient Test Requirements

Tests 21-27, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-4

SUPP

Supplementary Transient Test Requirements

Tests 28-34, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-5

SUPP

Supplementary Transient Test Requirements

Tests 35-40, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-6

SUPP

Supplementary Transient Test Requirements

Tests 41-47, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-7

SUPP

Supplementary Transient Test Requirements

Tests 48-53, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-8

SUPP

Supplementary Transient Test Requirements

Tests 54-62, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-9

SUPP

Supplementary Transient Test Requirements

Tests 63-74, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

HSUPP-10

SUPP

Supplementary Transient Test Requirements

Tests 1-6 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

HSUPP-11

SUPP

Supplementary Transient Test Requirements

Tests 7-12 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

HSUPP-12

SUPP

Supplementary Transient Test Requirements

Tests 13-15 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

HSUPP-13