AMETEK Compact i/iX Series Software Manual User Manual
Page 95
User Manual - Rev H
California Instruments
Avionics Software
95
1.7
Steady State Frequency (see Designer Notes)
360 to 800 Hz
Requirement fulfilled in 1.1 and 1.2
1.8
Frequency Modulation
Per Figure 2
2 mins each test (360, 800Hz nominal)
HVAC-18
2.0
Normal AC Transients
2.1
Voltage Transients
50ms Dropouts
800Hz and 360Hz
HVAC-21-1
2.1
Voltage Transients
Voltage Surge/Sag
3 times each, 800Hz and 360Hz
HVAC-21-2
2.1
Voltage Transients
Per Table B.2.1.1.1
2 times each
HVAC-21-3
2.2
Voltage Spikes
Per Figure 10
Requires additional equipment
2.3
Frequency Transients
2.3.1
Maximum Ramp Rate
100Hz/s up, 200Hz/s down
3 times each, 360Hz nominal
HVAC-23
3.0
Abnormal AC Steady State
3.1
Individual Phase Voltage
190.0 to 268.0 Volts RMS
Single Phase Unit Test
HVAC-31-1
3.1
Individual Phase Voltage
190.0 to 268.0 Volts RMS
Three Phase Unit Test
HVAC-31-2
3.2
Average of Three-Phase Voltages
193.0 to 265.0 Volts RMS
5 mins each test
HVAC-32
3.3
Abnormal Steady State Frequency (see Designer Notes)
360 to 800 Hz
Requirement fulfilled in 1.7
4.0
Abnormal AC Transients
4.1
Voltage Transients
Per Figure 5A
Apply each transient 3x with 10s interval
HVAC-41
4.2
Frequency Transients
4.2.1
Maximum Ramp Rate
100Hz/s up, 200Hz/s down
Test procedure TBD
4.2.2
Transients Outside of Steady State Range
Per Figure 6
Test procedure TBD
4.3
DC Content
Per Figure 11
Test procedure TBD
SUPP
Supplementary Transient Test Requirements
Tests 1-7, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-1
SUPP
Supplementary Transient Test Requirements
Tests 8-14, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-2
SUPP
Supplementary Transient Test Requirements
Tests 15-20, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-3
SUPP
Supplementary Transient Test Requirements
Tests 21-27, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-4
SUPP
Supplementary Transient Test Requirements
Tests 28-34, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-5
SUPP
Supplementary Transient Test Requirements
Tests 35-40, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-6
SUPP
Supplementary Transient Test Requirements
Tests 41-47, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-7
SUPP
Supplementary Transient Test Requirements
Tests 48-53, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-8
SUPP
Supplementary Transient Test Requirements
Tests 54-62, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-9
SUPP
Supplementary Transient Test Requirements
Tests 63-74, Table 3.3.2-3A
Tests performed at 360, 530, and 800 Hz
HSUPP-10
SUPP
Supplementary Transient Test Requirements
Tests 1-6 Table 3.3.2-3B
Tests performed at 360, 530, and 800 Hz
HSUPP-11
SUPP
Supplementary Transient Test Requirements
Tests 7-12 Table 3.3.2-3B
Tests performed at 360, 530, and 800 Hz
HSUPP-12
SUPP
Supplementary Transient Test Requirements
Tests 13-15 Table 3.3.2-3B
Tests performed at 360, 530, and 800 Hz
HSUPP-13