Table sxf – AMETEK Compact i/iX Series Software Manual User Manual
Page 113
User Manual - Rev H
California Instruments
Avionics Software
113
Test No. Section
Subject
Test Limits
Comment
File Ref.
800-1 800 Hz, Overvoltage Transients
Peak Voltage 180V RMS
Table TVF302-2 A-G
FTVF302-800-1
800-2 800 Hz, Undervoltage Transients
Low Voltage 45V RMS
Table TVF302-2 H-N
FTVF302-800-2
800-3 800 Hz, Combined Transient
45V RMS to 180V RMS
Table TVF302-2 O
FTVF302-800-3
TVF303
Abnormal Frequency Transients
1
Overfrequency Transients
High Frequency 800 Hz
Table TVF303-2 A-D
FTVF303-1
2
Underfrequency Transients
Low Frequency 360 Hz
Table TVF303-2 E-H
FTVF303-2
3
Combined Transient
360 Hz to 800 Hz
Table TVF303-2 I
FTVF303-3
TVF401
Emergency Limits for Voltage and Frequency
Perform Test TVF102
TVF501
No Tests
N/A to AC Utilization Equipment
TVF601
Power Failure (Single Phase)
400-1 115V RMS, 400 Hz nominal settings
0V for 7 seconds
Table TVF601-2
FTVF601-400-1
360-1 115V RMS, 360 Hz nominal settings
0V for 7 seconds
Table TVF601-2
FTVF601-360-1
600-1 115V RMS, 600 Hz nominal settings
0V for 7 seconds
Table TVF601-2
FTVF601-600-1
800-1 115V RMS, 800 Hz nominal settings
0V for 7 seconds
Table TVF601-2
FTVF601-800-1
TVF602
One Phase and Two Phase Power Failures
400-1 One Phase Power Failures
0V for 7 seconds
Table TVF602-2 A-F
FTVF602-400-1
400-2 Two Phase Power Failures
0V for 30 mins
Table TVF602-2 G-J
FTVF602-400-2
360-1 One Phase Power Failures
0V for 7 seconds
Table TVF602-2 A-F
FTVF602-360-1
360-2 Two Phase Power Failures
0V for 30 mins
Table TVF602-2 G-J
FTVF602-360-2
600-1 One Phase Power Failures
0V for 7 seconds
Table TVF602-2 A-F
FTVF602-600-1
600-2 Two Phase Power Failures
0V for 30 mins
Table TVF602-2 G-J
FTVF602-600-2
800-1 One Phase Power Failures
0V for 7 seconds
Table TVF602-2 A-F
FTVF602-800-1
800-2 Two Phase Power Failures
0V for 30 mins
Table TVF602-2 G-J
FTVF602-800-2
TVF603
Phase Reversal
Phase reversal done physically FTVF603
5.3.1.5
Table SXF:
Test No. Section
Subject
Test Limits
Comment
File Ref.
SXF101
Load and Current Harmonic Measurements
115V RMS, 60 Hz
FSXF101
SXF102
Steady State Limits for Voltage and Frequency
105V to 125V RMS, 59.75 to 60.25 Hz
Apply for 30 mins each test
FSXF102
SXF103
No Test, Done so test numbers coincide
SXF104
Voltage Modulation
1
115V Nominal Test
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FSXF104-1
2
109V Nominal Test
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FSXF104-2
3
117V Nominal Test
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FSXF104-3
SXF105
Frequency Modulation
1
60 Hz Nominal Test
60 Hz, .5 Hz mod
Apply for 10+ mins
FSXF105-1
2
59.75 Hz Nominal Test
59.75 Hz, .5 Hz mod
Apply for 10+ mins
FSXF105-2
3
60.75 Hz Nominal Test
60.75 Hz, .5 Hz mod
Apply for 10+ mins
FSXF105-3
SXF106
Voltage Distortion Spectrum
Requires Additional Equipment
SXF107
Total Voltage Distortion
Voltage Distortion Factor 0.05
Apply for 30 mins
FSXF107
SXF108
DC Voltage Component
1
Positive DC Offset
115V RMS + .10V DC
Apply for 30 mins
FSXF108-1
2
Negative DC Offset
115V RMS - .10V DC
Apply for 30 mins
FSXF108-2