beautypg.com

AMETEK Compact i/iX Series Software Manual User Manual

Page 66

background image

User Manual

– Rev H

California Instruments

66

Avionics Software

4.0

Abnormal AC Transients

4.1

Voltage Transients

Per Figure 5A

Apply each transient 3x with 10s interval

LVAC-41

4.2

Frequency Variations

4.2.1

Maximum Ramp Rate

120Hz/s up, 400Hz/s down

3 times each, 360Hz nominal

LVAC-42-1

4.2.2

Frequency Transients

350 to 885 Hz

3 times each, 400Hz nominal

LVAC-42-2

4.3

DC Content

+/- 55VDC offset

800Hz and 360Hz

LVAC-43

SUPP

Supplementary Transient Test Requirements

Tests 1-7, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-1

SUPP

Supplementary Transient Test Requirements

Tests 8-14, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-2

SUPP

Supplementary Transient Test Requirements

Tests 15-20, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-3

SUPP

Supplementary Transient Test Requirements

Tests 21-27, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-4

SUPP

Supplementary Transient Test Requirements

Tests 28-34, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-5

SUPP

Supplementary Transient Test Requirements

Tests 35-40, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-6

SUPP

Supplementary Transient Test Requirements

Tests 41-47, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-7

SUPP

Supplementary Transient Test Requirements

Tests 48-53, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-8

SUPP

Supplementary Transient Test Requirements

Tests 54-62, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-9

SUPP

Supplementary Transient Test Requirements

Tests 63-74, Table 3.3.2-3A

Tests performed at 360, 680, and 800 Hz

LSUPP-10

SUPP

Supplementary Transient Test Requirements

Tests 1-6 Table 3.3.2-3B

Tests performed at 360, 680, and 800 Hz

LSUPP-11

SUPP

Supplementary Transient Test Requirements

Tests 7-12 Table 3.3.2-3B

Tests performed at 360, 680, and 800 Hz

LSUPP-12

SUPP

Supplementary Transient Test Requirements

Tests 13-18 Table 3.3.2-3B

Tests performed at 360, 680, and 800 Hz

LSUPP-13

SUPP

Supplementary Transient Test Requirements

Test 19 Table 3.3.2-3B

Tests performed at 360, 680, and 800 Hz

LSUPP-14