235vac – AMETEK Compact i/iX Series Software Manual User Manual
Page 83
User Manual - Rev H
California Instruments
Avionics Software
83
4.4.2.3
235VAC:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
1.0
Normal AC Steady State
1.1
Individual Phase Voltage
190.0 to 244.0 Volts RMS
30 mins, 800Hz and 360Hz
HVAC-11
1.2
Average of Three-Phase Voltages
193.0 to 241.0 Volts RMS
30 mins, 800Hz and 360Hz
HVAC-12
1.3
Phase Displacement
120.0 +/- 4.0°
No specified test
1.4
Phase Voltage Unbalance
Max. 12.0 Volts RMS
Apply each test 30 mins
HVAC-14
1.5
AC Voltage Modulation
1.5.1
Maximum Amplitude
10.0 Volts Peak-to-Valley
Follows specification Figure 1
HVAC-15
1.5.2
Frequency Components
Per Figure 1
Figure only, not a test. (Refer to spec)
1.6
Voltage Waveform
1.6.1
Total Harmonic Content
Max. 10% of Fundamental
30 mins each test
HVAC-16-1
1.6.2
Individual Harmonic Content
Max. 8% of Fundamental
Requires audio generator
1.6.3
DC Content
+/-0.20 Volts (after first cycle)
30 mins each test
HVAC-16-2
1.6.4
Crest Factor
1.41 +/- 0.15
No specified test
1.7
Steady State Frequency (see Designer Notes)
360 to 800 Hz
Requirement fulfilled in 1.1 and 1.2
1.8
Frequency Modulation
Applies to Ground Handling Equip only
2.0
Normal AC Transients
2.1
Voltage Transients
50ms Dropouts
800Hz and 360Hz
HVAC-21-1
2.1
Voltage Transients
Voltage Surge/Sag
3 times each, 800Hz and 360Hz
HVAC-21-2
2.1
Voltage Transients
Per Table B.2.1.1.1
2 times each
HVAC-21-3
2.2
Voltage Spikes
Per Figure 10
Requires additional equipment
2.3.1
Frequency Variations - Max Ramp Rate
100Hz/s up, 200Hz/s down
3 times each, 360Hz nominal
HVAC-23
2.3.2
Frequency Variations - Frequency Transients
Applies to Ground Handling Equip only
3.0
Abnormal AC Steady State
3.1
Individual Phase Voltage
190.0 to 268.0 Volts RMS
Single Phase Unit Test
HVAC-31-1
3.1
Average of Three-Phase Voltages
193.0 to 265.0 Volts RMS
5 mins each test
HVAC-31-2
3.2
Average of Three-Phase Voltages
190.0 to 268.0 Volts RMS
Three Phase Unit Test
HVAC-32
3.3
Abnormal Steady State Frequency (see Designer Notes)
360 to 800 Hz
Requirement fulfilled in 1.7
4.0
Abnormal AC Transients
4.1
Voltage Transients
Per Figure 5A
Apply each transient 3x with 10s interval
HVAC-41
4.2
Frequency Transients
4.2.1
Maximum Ramp Rate
120Hz/s up, 400Hz/s down
3 times each, 360Hz nominal
HVAC-42-1
4.2.2
Transients Outside of Steady State Range
350 to 885 Hz
3 times each, 400Hz nominal
HVAC-42-2