beautypg.com

235vac for ground handling equipment – AMETEK Compact i/iX Series Software Manual User Manual

Page 71

background image

User Manual - Rev H

California Instruments

Avionics Software

71

4.4.1.4

235VAC for Ground Handling Equipment:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

1.0

Normal AC Steady State

1.1

Individual Phase Voltage

190.0 to 244.0 Volts RMS

30 mins, 441Hz and 360Hz

GHHVAC-11

1.2

Average of Three-Phase Voltages

193.0 to 241.0 Volts RMS

30 mins, 441Hz and 360Hz

GHHVAC-12

1.3

Phase Displacement

120.0 +/- 4.0°

No specified test

1.4

Phase Voltage Unbalance

Max. 12.0 Volts RMS

Apply each test 30 mins

GHHVAC-14

1.5

AC Voltage Modulation

1.5.1

Maximum Amplitude

10.0 Volts Peak-to-Valley

Follows specification Figure 1

GHHVAC-15

1.5.2

Frequency Components

Per Figure 1

Figure only, not a test. (Refer to spec)

1.6

Voltage Waveform

1.6.1

Total Harmonic Content

Max. 10% of Fundamental

30 mins each test

GHHVAC-16-1

1.6.2

Individual Harmonic Content

Max. 8% of Fundamental

Requires audio generator

1.6.3

DC Content

+/-0.20 Volts (after first cycle)

30 mins each test

GHHVAC-16-3

1.6.4

Crest Factor

1.41 +/- 0.15

No specified test

1.7

Steady State Frequency (see Designer Notes)

360 to 441 Hz

Requirement fulfilled in 1.1 and 1.2

1.8

Frequency Modulation

Applies to Ground Handling Equip only

2.0

Normal AC Transients

2.1

Voltage Transients

50ms Dropouts

441Hz and 360Hz

GHHVAC-21-1

2.1

Voltage Transients

Voltage Surge/Sag

3 times each, 441Hz and 360Hz

GHHVAC-21-2

2.1

Voltage Transients

Per Table 3.3.2-6

2 times each

GHHVAC-21-3

2.2

Voltage Spikes

Per Figure 10

Requires additional equipment

2.3.1

Frequency Variations - Max Ramp Rate

100Hz/s up, 200Hz/s down

N/A for GHE

2.3.2

Frequency Variations - Frequency Transients

Applies to Ground Handling Equip only

GHHVAC-23

3.0

Abnormal AC Steady State

3.1

Individual Phase Voltage

190.0 to 268.0 Volts RMS

Single Phase Unit Test

GHHVAC-31

3.2

Average of Three-Phase Voltages

193.0 to 265.0 Volts RMS

5 mins each test

GHHVAC-32-1

3.2

Average of Three-Phase Voltages

190.0 to 268.0 Volts RMS

Three Phase Unit Test

GHHVAC-32-2

3.3

Abnormal Steady State Frequency (see Designer Notes)

360 to 441 Hz

Requirement fulfilled in 1.7

4.0

Abnormal AC Transients

4.1

Voltage Transients

Per Figure 5A

Apply each transient 3x with 10s interval

GHHVAC-41

4.2

Frequency Transients

4.2.1

Maximum Ramp Rate

120Hz/s up, 400Hz/s down

N/A for GHE

4.2.2

Transients Outside of Steady State Range

350 to 480 Hz

3 times each, 400Hz nominal

GHHVAC-42-2