Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual
Page 50
User Manual
– Rev H
California Instruments
50
Avionics Software
3.4.2.5
Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b Voltage (Average Value dc)
22.0V to 30.3V
Apply for 30 mins each test
FBDC28_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3) Voltage (Average Value dc)
18.0V
Apply for 30 mins each test
FBDC28_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = 1.6V, Freq = 200Hz
Figure 18-2
FBDC28_VRIP
16.6.1.3b Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
FBDC28_PINTB
16.6.1.3c Momentary Power Interruptions (dc)
Other Equipment
FBDC28_PINTC
16.6.1.4 Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
47V to 17V
FBDC28_NVSUR
16.6.1.5
Engine Starting Under Voltage Operation
(dc)
10V min
Slew for 35 sec
FBDC28_VENG
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1 Voltage Steady State (dc)
20.5V to 32.2V
Apply for 5 mins each test
FBDC28_VABN
16.6.2.2 Low Voltage Conditions (dc)
0V over 10 minutes
FBDC28_LVABN
16.6.2.3 Momentary Undervoltage (dc)
12V
Apply for 7 seconds each test
FBDC28_VUND
16.6.2.4 Abnormal Transients (ac)
16.6.2.4d - Abnormal Voltage Surge
60VDC
Figure 16-4 - apply at 10 sec
intervals
FBDC28_AVSUR
1
For more comprehensive DC Ripple tests, refer to section 3.3.