beautypg.com

Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual

Page 50

background image

User Manual

– Rev H

California Instruments

50

Avionics Software

3.4.2.5

Table A(CF)115:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

16.6.1

Normal Operating Conditions (dc)

16.6.1.1b Voltage (Average Value dc)

22.0V to 30.3V

Apply for 30 mins each test

FBDC28_VAVG

16.6.1

Emergency Operating Conditions (dc)

16.6.1.1b(3) Voltage (Average Value dc)

18.0V

Apply for 30 mins each test

FBDC28_VAVGEMER

16.6.1

Normal Operating Conditions (dc)

16.6.1.2

1

Ripple Voltage (dc)

Vp-p = 1.6V, Freq = 200Hz

Figure 18-2

FBDC28_VRIP

16.6.1.3b Momentary Power Interruptions (dc)

Table 16-3

Equipment with Digital Circuits

FBDC28_PINTB

16.6.1.3c Momentary Power Interruptions (dc)

Other Equipment

FBDC28_PINTC

16.6.1.4 Normal Transients (dc)

16.6.1.4b - Normal Voltage Surge (dc)

47V to 17V

FBDC28_NVSUR

16.6.1.5

Engine Starting Under Voltage Operation
(dc)

10V min

Slew for 35 sec

FBDC28_VENG

16.6.2

Abnormal Operating Conditions (dc)

16.6.2.1 Voltage Steady State (dc)

20.5V to 32.2V

Apply for 5 mins each test

FBDC28_VABN

16.6.2.2 Low Voltage Conditions (dc)

0V over 10 minutes

FBDC28_LVABN

16.6.2.3 Momentary Undervoltage (dc)

12V

Apply for 7 seconds each test

FBDC28_VUND

16.6.2.4 Abnormal Transients (ac)

16.6.2.4d - Abnormal Voltage Surge

60VDC

Figure 16-4 - apply at 10 sec
intervals

FBDC28_AVSUR














1

For more comprehensive DC Ripple tests, refer to section 3.3.