AMETEK Compact i/iX Series Software Manual User Manual
Page 68
User Manual
– Rev H
California Instruments
68
Avionics Software
4.2.1
Maximum Ramp Rate
120Hz/s up, 400Hz/s down
N/A for GHE
4.2.2
Frequency Transients
350 to 480 Hz
3 times each, 400Hz nominal
GHLVAC-42-2
4.3
DC Content
+/- 55VDC offset
441Hz and 360Hz
GHLVAC-43
SUPP
Supplementary Transient Test Requirements
Tests 1-10, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-1
SUPP
Supplementary Transient Test Requirements
Tests 11-20, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-2
SUPP
Supplementary Transient Test Requirements
Tests 21-30, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-3
SUPP
Supplementary Transient Test Requirements
Tests 31-40, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-4
SUPP
Supplementary Transient Test Requirements
Tests 41-50, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-5
SUPP
Supplementary Transient Test Requirements
Tests 51-62, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-6
SUPP
Supplementary Transient Test Requirements
Tests 63-74, Table 3.3.2-3A
Tests performed at 360 and 441 Hz
GHLSUPP-7
SUPP
Supplementary Transient Test Requirements
Tests 1-11 Table 3.3.2-3B
Tests performed at 360 and 441 Hz
GHLSUPP-8
SUPP
Supplementary Transient Test Requirements
Tests 12-19 Table 3.3.2-3B
Tests performed at 360 and 441 Hz
GHLSUPP-9