Table SAC:

Test No. Section

Subject

Test Limits

Comment

File Ref.

SAC101

Load and Current Harmonic Measurements

115V RMS, 400 Hz

BSAC101

SAC102

Steady State Limits for Voltage and Frequency

1

Regular Test

108V to 118V RMS, 395 to 405 Hz

Apply for 30 mins each test

BSAC102-1

2

Helicopter Test

108V to 118V RMS, 380 to 420 Hz

Apply for 30 mins each test

BSAC102-2

SAC103

No Test, Done so test numbers coincide

SAC104

Voltage Modulation

1

115V Nominal Test

115V RMS, 2.5V RMS mod

Apply for 10+ mins

BSAC104-1

2

109V Nominal Test

109V RMS, 2.5V RMS mod

Apply for 10+ mins

BSAC104-2

3

117V Nominal Test

117V RMS, 2.5V RMS mod

Apply for 10+ mins

BSAC104-3

SAC105

Frequency Modulation

1

400 Hz Nominal Test

400 Hz, +/-5 Hz mod

Apply for 10+ mins

BSAC105-1

2

395 Hz Nominal Test

395 Hz, +/-5 Hz mod

Apply for 10+ mins

BSAC105-2

3

405 Hz Nominal Test

405 Hz, +/-5 Hz mod

Apply for 10+ mins

BSAC105-3

SAC106

Voltage Distortion Spectrum

Requires Additional Equipment

SAC107

Total Voltage Distortion

Voltage Distortion Factor 0.05

Apply for 30 mins

BSAC107

SAC108

DC Voltage Component

1

Positive DC Offset

115V RMS + .10V DC

Apply for 30 mins

BSAC108-1

2

Negative DC Offset

115V RMS - .10V DC

Apply for 30 mins

BSAC108-2

SAC109

Normal Voltage Transients

180V RMS to 80V RMS

1

Overvoltage Transients

Peak voltage 180V RMS

Table SAC109-3 AA-GG

BSAC109-1

2

Undervoltage Transients

Low voltage 80V RMS

Table SAC109-3 HH-LL

BSAC109-2

3

Combined Transient

180V RMS to 80V RMS

Table SAC109-3 MM

BSAC109-3

4

Repetitive Normal Voltage Transient Test

90V RMS to 140V RMS

Run transient for 30 mins

BSAC109-4

SAC110

Normal Frequency Transients

375 Hz to 425 Hz

1

Overfrequency Transients

High Frequency 425 Hz

Table SAC110-3 AA-DD

BSAC110-1

2

Underfrequency Transients

Low Frequency 375 Hz

Table SAC110-3 EE-HH

BSAC110-2

3

Combined Transient

375 Hz to 425 Hz

Table SAC110-3 II

BSAC110-3

SAC201

Power Interrupt

0V for 50 msec

Table SAC201-2 A-L

BSAC201

SAC301

Abnormal Steady State Limits for Voltage and Frequency

100V RMS to 125V RMS, 375 Hz to 425 Hz Apply for 30 mins

BSAC301

SAC302

Abnormal Voltage Transients

45V RMS to 180V RMS

1

Overvoltage Transients

Peak voltage 180V RMS

Table SAC302-3 AA-GG

BSAC302-1

2

Undervoltage Transients

Low voltage 45V RMS

Table SAC302-3 HH-NN

BSAC302-2

3

Combined Transient

45V RMS to 180V RMS

Table SAC302-3 OO

BSAC302-3

SAC303

Abnormal Frequency Transients

320 Hz to 480 Hz

Table SAC303-3 AA-EE

BSAC303

SAC401

Emergency Steady State Limits for Voltage and Frequency

102V to 124V RMS, 360 to 440 Hz

Apply for 30 mins each test

BSAC401

SAC501

No Tests

N/A to AC Utilization Equipment

SAC601

Power Failure (Single Phase)

0V for 7 seconds

Table SAC601-2 A-D

BSAC601

SAC602

Power Failure

No test, done so numbers coincide