beautypg.com

Rev c, Table svf – AMETEK Compact i/iX Series Software Manual User Manual

Page 195

background image

User Manual - Rev H

California Instruments

Avionics Software

195

8.4.1

Rev C:

8.4.1.1

Table SVF:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

SVF101

Steady State Voltage and Frequency

104 to 122 Volts RMS

DO160 16.5.1.1.b, 620Hz and
390Hz

SVF101

SVF102

Voltage Transients

Surge to 160Vac max, Sag to 71Vac min

DO160 16.5.1.5.1.b, 620Hz and
390Hz

SVF102

SVF103

Voltage Modulation

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

DO160 16.5.1.2, 620Hz and 390Hz

SVF103

SVF104

Voltage Spikes

Requires Additional Equipment

SVF105

Current Distortion

115Vnom, 390-620 Hz

Limits defined by Table A.4

SVF105

SVF106

Voltage Distortion

10% distortion

30sec each frequency

SVF106

SVF106

EW

Voltage Distortion - Endurance test with motor

10% distortion

Per Table SVF 106-2

SVF106-EW

SVF106

E

Voltage Distortion - Endurance test without motor

10% distortion

Per Table SVF 106-2

SVF106-E

SVF107

Inrush Current

Test requires multiple load cables

Test not performed with software

SVF108

Frequency Variations

Slew from 390 to 620Hz, 100Hz/s up and down

3 times each

SVF108

SVF109

Frequency Modulation

Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to
100Hz

DO160 16.5.1.3, 620Hz and 390Hz

SVF109

SVF110

Voltage DC Content

+/-.3VDC Offset

30 mins each test

SVF110

SVF111

Voltage Modulation due to Equipment

Test requires special cables

Test not performed with software

SVF112

Voltage Spike Due to Equipment Load Switching

Requires Additional Equipment

SVF201

Abnormal Steady State Voltage and Frequency

96 to 130 Volts RMS

DO160 16.5.2.1.b, 620Hz and
390Hz

SVF201

SVF202

Abnormal Voltage Transients

Surge to 180Vac max, Sag to 0Vac min

DO160 16.5.2.2.b, 620Hz and
390Hz

SVF202

SVF203

Abnormal Voltage Modulation

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

DO160 16.5.1.2, 620Hz and 390Hz

SVF203

SVF301

Emergency Steady State Voltage and Frequency

104 to 122 Volts RMS

DO160 16.5.1.1.b, 620Hz and
390Hz

SVF301

SVF302

Emergency Voltage Distortion

15% distortion

30sec each frequency

SVF302

SVF302

EW

Voltage Distortion - Endurance test with motor

15% distortion

Per Table SVF 302-2

SVF302-EW

SVF302

E

Voltage Distortion - Endurance test without motor

15% distortion

Per Table SVF 302-2

SVF302-E

SVF303

Emergency Voltage Distortion Transients

25% distortion

10 times each test

SVF303

SVF304

Emergency Frequency Variations

Slew from 390 to 620Hz, 500Hz/s up and down

3 times each

SVF304

SVF305

Emergency Voltage Modulation due to Equipment

Test requires special cables

Test not performed with software