AMETEK Compact i/iX Series Software Manual User Manual
Page 148
User Manual
– Rev H
California Instruments
148
Avionics Software
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
26
TVF203
2
Voltage Modulation
130V, 360Hz
Appendix A, Table A.3
TVF203-2
27
TVF203
3
Voltage Modulation
96V, 900Hz
Appendix A, Table A.3
TVF203-3
28
TVF203
4
Voltage Modulation
130V, 900Hz
Appendix A, Table A.3
TVF203-4
29
Emergency Operation
30
TVF301
Steady State Voltage and
Frequency
100V to 120.5V,
360Hz and 900Hz
16.5.1.1.c.1
Same as TVF101
TVF101
31
TVF302
1
Voltage Distortion 1
Distortion limits
Appendix D
TVF302-1
32
TVF302
2
VTHD 1 - No motor
Endurance
Appendix D
TVF302-2
33
TVF302
2M
VTHD 1 - EUT incl. motor
Endurance
Appendix D
TVF302-2M
34
TVF303
Voltage Distortion 2
1400Hz to 150KHz
Section 18, Figure 18-1
Not supported, additional equipment
required.
35
TVF304
Voltage Distortion Transients
Distortion limits
Appendix B, Figure B.15
TVF304
36
TVF305
Inrush current
109.5V to 120.5V
RMS
App B, Figure B.18,B19
TVF305
37
TVF306
Frequency Variations
360Hz to 900Hz,
1000Hz/s
Appendix A, Table A.4
TVF306
38
TVF307
VMod due to equipment.
109.5V to 120.5V,
360Hz and 900Hz
App A, Table A.3, App B, Fig B.2
TVF307
39
Switching Transients
40
TVF401
1
Transparency Time.
100V, 360Hz, 10ms
Fig TVF401-1, Table TVF401-1
TVF401-1
41
TVF401
2
Transparency Time.
100V, 900Hz, 10ms
Fig TVF401-1, Table TVF401-1
TVF401-2
42
TVF402
Voltage switching transients 1
100V, 360Hz and
900Hz, 2ms to 200ms
Use ABD0100.8.1 Switching transients
screen Fig A
43
TVF403
Voltage switching transients 2
100V, 360Hz and
900Hz, 0ms to
5000ms
Use ABD0100.8.1 Switching transients
screen Fig B, Table 1.1
44
TVF404
Volt switch trans with freq change
100V, 360Hz and
900Hz, 50ms to
200ms
Appendix A, Table A.4
TVF404
45
Power Supply Removal
46
TVF501
Power line disconnection
115V 360Hz and
900Hz
TVF501