Table tac – AMETEK Compact i/iX Series Software Manual User Manual
Page 108
User Manual
– Rev H
California Instruments
108
Avionics Software
5.3.1.2
Table TAC:
Test No. Section
Subject
Test Limits
Comment
File Ref.
TAC101
Three Phase Load and Current Harmonic Measurements
115V RMS, 400 Hz
FTAC101
TAC102
Steady State Limits for Voltage (Including Unbalance) and Frequency
1
Balanced Phases
108V to 118V RMS, 393 to 407 Hz
Apply for 30 mins each test
FTAC102-1
2
Unbalanced Phases
108V to 118V RMS, +/- 3V Unbalance
Apply for 30 mins each test
FTAC102-2
TAC103
Voltage Phase Difference
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTAC103
TAC104
Voltage Modulation
1
115V Nominal Test
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-1
2
109V Nominal Test
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-2
3
117V Nominal Test
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-3
TAC105
Frequency Modulation
1
400 Hz Nominal Test
400 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-1
2
395 Hz Nominal Test
395 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-2
3
405 Hz Nominal Test
405 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-3
TAC106
Voltage Distortion Spectrum
Requires Additional Equipment
TAC107
Total Voltage Distortion
Voltage Distortion Factor 0.05
Apply for 30 mins
FTAC107
TAC108
DC Voltage Component
1
Positive DC Offset
115V RMS + .10V DC
Apply for 30 mins
FTAC108-1
2
Negative DC Offset
115V RMS - .10V DC
Apply for 30 mins
FTAC108-2
TAC109
Normal Voltage Transients
180V RMS to 80V RMS
1
Overvoltage Transients
Peak voltage 180V RMS
Table TAC109-3 AA-GG
FTAC109-1
2
Undervoltage Transients
Low voltage 80V RMS
Table TAC109-3 HH-LL
FTAC109-2
3
Combined Transient
180V RMS to 80V RMS
Table TAC109-3 MM
FTAC109-3
4
Repetitive Normal Voltage Transient Test
90V RMS to 140V RMS
Run transient for 30 mins
FTAC109-4
TAC110
Normal Frequency Transients
375 Hz to 425 Hz
1
Overfrequency Transients
High Frequency 425 Hz
Table TAC110-3 AA-DD
FTAC110-1
2
Underfrequency Transients
Low Frequency 375 Hz
Table TAC110-3 EE-HH
FTAC110-2
3
Combined Transient
375 Hz to 425 Hz
Table TAC110-3 II
FTAC110-3
TAC201
Power Interrupt
0V for 50 msec
Table TAC201-2 A-L
FTAC201
TAC301
Abnormal Steady State Limits for Voltage and Frequency
100V RMS to 125V RMS, 380 Hz to 420
Hz
Apply for 30 mins
FTAC301
TAC302
Abnormal Voltage Transients
45V RMS to 180V RMS
1
Overvoltage Transients
Peak voltage 180V RMS
Table TAC302-3 AA-GG
FTAC302-1
2
Undervoltage Transients
Low voltage 45V RMS
Table TAC302-3 HH-NN
FTAC302-2
3
Combined Transient
45V RMS to 180V RMS
Table TAC302-3 OO
FTAC302-3
TAC303
Abnormal Frequency Transients
320 Hz to 480 Hz
Table TAC303-3 AA-EE
FTAC303
TAC401
Emergency Steady State Limits for Voltage and Frequency
Perform Test TAC102
TAC501
No Tests
N/A to AC Utilization Equipment
TAC601
Power Failure (Three Phase)
0V for 7 seconds
Table TAC601-2 A-D
FTAC601
TAC602
One Phase and Two Phase Power Failures
1
One Phase Power Failures
0V for 7 seconds
Table TAC602-2 A-F
FTAC602-1
2
Two Phase Power Failures
0V for 30 mins
Table TAC602-2 G-J
FTAC602-2
TAC603
Phase Reversal
Phase reversal done physically
FTAC603