6.3.1.7

SVFH:

#

Test

No.

Subject

Test Limits

DO160 Ref.

Comments

Test File

1

Normal Operation

2

SVFH101

Steady State Voltage and
frequency

202.0V to 248.0V
RMS

16.5.1.1.c.1 (1)

Apply at 360Hz and 900Hz

SVFH101

3

SVFH102

Voltage Transients

136V to 324V RMS

16.5.1.5.b

Appendix A, Table C.4

SVFH102

4

SVFH103

1

Voltage Modulation

202.0V RMS, 360 Hz

16.5.1.5.b

Appendix B, Figure B.2

SVFH103-1

5

SVFH103

2

Voltage Modulation

248.0V RMS, 360 Hz

16.5.1.5.b

Appendix B, Figure B.2

SVFH103-2

6

SVFH103

3

Voltage Modulation

202.0V RMS, 900 Hz

16.5.1.5.b

Appendix B, Figure B.2

SVFH103-3

7

SVFH103

4

Voltage Modulation

248.0V RMS, 900 Hz

16.5.1.5.b

Appendix B, Figure B.2

SVFH103-4

8

SVFH104

Voltage Spikes

184V to 1000V

17.4, Figure 17.4

Not supported, additional equipment
required.

9

SVFH105

Current Distortion

Requires external HF
power analyzer

App A, Tables A.7, A.8, App B, Fig
B.14

SVFH105

10

SVFH106

1

Voltage Distortion 1

Distortion limits

Appendix D

SVFH106-1

11

SVFH106

2

VTHD 1 - No motor

Endurance

Appendix D

SVFH106-2

12

SVFH106

2M

VTHD 1 - EUT incl. motor

Endurance

Appendix D

SVFH106-2M

13

SVFH107

Voltage Distortion 2

700Hz to 150KHz

Section 18, Figure 18-1

Not supported, additional equipment
required.

14

SVFH108

Voltage Distortion Transients

Distortion limits

Appendix D

SVFH108

15

SVFH109

Inrush current

200V to 260V RMS

App B, Figure B.18,B19

SVFH109

16

SVFH110

Frequency Variations

360Hz to 900Hz,
100Hz/s

Appendix A, Table A.4

SVFH110

17

SVFH111

Frequency Modulation

360Hz and 900Hz

Appendix B, Figure B.10

SVFH111

18

SVFH112

Voltage DC Content

-0.6Vdc and +0.6Vdc

Appendix B, Figure B.17

SVFH112

19

SVFH113

VMod due to equipment.

200V to 260V, 360Hz
and 900Hz

App A, Table A.3, App B, Fig B.2

SVFH113

20

SVFH114

VSpike due to equipment.

230V, 360Hz and
900Hz

App B, Fig 4. Requires external
contactors

SVFH114

21

Abnormal Operation

22

SVFH201

Steady State Voltage and
Frequency

192V to 260V, 360Hz
and 900Hz

16.5.2.1.c

Appendix A, Table A.3

SVFH201

23

SVFH202

Voltage Transients

0V to 360V, 360Hz
and 900Hz

16.5.2.2.b & 16.5.2.2.b

Appendix A, Table A.4

SVFH202

24

SVFH203

1

Voltage Modulation

192V , 360Hz

Appendix A, Table A.3

SVFH203-1

25

SVFH203

2

Voltage Modulation

260V, 360Hz

Appendix A, Table A.3