Avionics Software

16.5.2.3.1 - Abnormal Voltage surge

148V to 180V, 360Hz

Figure 16.5 - apply at 10 sec intervals FANF115_AVSUR360

16.5.2.3.1 - Abnormal Voltage surge

148V to 180V, 650Hz

Figure 16.5 - apply at 10 sec intervals FANF115_AVSUR650


3.4.2.3

Table A(CF)115:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

16.5.1

Normal Operating Conditions (ac)

16.5.1.1b(1) 1 Phs Voltage and Frequency (ac)

100V to 122V, 360Hz to 800Hz

Apply for 30 mins each test

FAWF115_VFNORM1P

16.5.1.1c.2(1) 3 Phs Voltage and Frequency (ac)

100V to 122V, 360Hz to 800Hz

Apply for 30 mins each test

FAWF115_VFNORM3P

16.5.1

Emergency Operating Conditions (ac)

16.5.1.1c.2(2) 3 Phs Voltage and Frequency (ac)

100V to 122V, 360Hz to 800Hz

Apply for 30 mins each test

FAWF115_VFEMER3P

16.5.1

Normal Operating Conditions (ac)

16.5.1.2

Voltage Modulation 360Hz (ac)

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

Figure 16-1

FAWF115_VMOD360

16.5.1.2

Voltage Modulation 800Hz (ac)

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

Figure 16-1

FAWF115_VMOD800

16.5.1.3

Frequency Modulation 360Hz (ac)

Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to
100Hz

Figure 16-2

FAWF115_FMOD360

16.5.1.3

Frequency Modulation 800Hz (ac)

Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to
100Hz

Figure 16-2

FAWF115_FMOD800

16.5.1.4b

Momentary Power Interruptions (ac)

Table 16-1 360Hz nom

Equipment with Digital Circuits

FAWF115_PINTB360

16.5.1.4b

Momentary Power Interruptions (ac)

Table 16-1 800Hz nom

Equipment with Digital Circuits

FAWF115_PINTB800

16.5.1.4c

Momentary Power Interruptions (ac)

360Hz nom

Other Equipment

FAWF115_PINTC360

16.5.1.4c

Momentary Power Interruptions (ac)

800Hz nom

Other Equipment

FAWF115_PINTC800

16.5.1.4d

Momentary Power Interruptions (ac)

Table 16-2

Additional Requirement (Var Freq)

FAWF115_PINTD

16.5.1.5

Normal Transients (ac)

16.5.1.5.1 - Normal Voltage Surge (ac) 160V to 70V, 360 Hz

FAWF115_NVSUR360

16.5.1.5.1 - Normal Voltage Surge (ac) 160V to 70V, 800 Hz

FAWF115_NVSUR800

16.5.1.6

Normal Frequency Surge (ac)

115V, 360Hz to 800Hz

FAWF115_NFSUR

16.5.1.7

Voltage DC Content (ac)

16.5.1.7 - 1 Phs Voltage DC Content
(ac)

± 0.1VDC (360Hz nom)

Apply for 30 mins each test

FAWF115_DCOFS1P360

16.5.1.7 - 1 Phs Voltage DC Content
(ac)

± 0.1VDC (800Hz nom)

Apply for 30 mins each test

FAWF115_DCOFS1P800

16.5.1.7 - 3 Phs Voltage DC Content
(ac)

± 0.1VDC (360Hz nom)

Apply for 30 mins each test

FAWF115_DCOFS3P360

16.5.1.7 - 3 Phs Voltage DC Content
(ac)

± 0.1VDC (800Hz nom)

Apply for 30 mins each test

FAWF115_DCOFS3P800

16.5.1.8

Voltage Distortion (ac)

10% +2%/-0% VTHD - Clipped Sine, 360Hz

Apply for 30 mins each test

FAWF115_VTHD360

16.5.1.8

Voltage Distortion (ac)

10% +2%/-0% VTHD - Clipped Sine, 800Hz

Apply for 30 mins each test

FAWF115_VTHD800

16.5.2