135

DC A350 Power Groups

– iX Series & Compact iX Series.

DC Power Groups

No.

Description

LDC

Normal Operation

YES

101

Steady-state voltage

YES

102

Voltage transients

YES

103

Voltage ripple

X

104

Voltage spikes

X

105

Inrush current

YES

106

Voltage variation APU start

YES

107

Equipment current ripple

X

108

Voltage spike due to load

YES

109

EPDC voltage clamping

YES

Abnormal Operation

201

Steady-state voltage

YES

202

Voltage transients

YES

203

Voltage ripple

X

Emergency Operation

301

Steady state voltage

YES

302

Voltage ripple

X

303

Inrush current

YES

304

Equipment Ripple

X

Switching Transients

401

Transparency time

YES

402

Voltage switching transients 1

(1)

403

Voltage switching transients 2

(1)

Power Supply Removal

501

Power line disconnection

YES

Note (1): Provided through ABD Switching Transients test menu.