TVF501
Power Failure
Test requires physically removing line cables
Test not performed with software
8.4.1.3
Table SCF:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
SCF101
Steady State Voltage and Frequency
104 to 122 Volts RMS
DO160 16.5.1.1.b, 410Hz and
390Hz
SCF101
SCF102
Voltage Transients
Surge to 160Vac max, Sag to 71Vac min
DO160 16.5.1.5.1.b, 400Hz
SCF102
SCF103
Voltage Modulation
Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz
DO160 16.5.1.2, 400Hz
SCF103
SCF104
Voltage Spikes
Requires Additional Equipment
SCF105
Current Distortion
115Vnom, 400 Hz
Limits defined by Table A.4
SCF105
SCF106
Voltage Distortion
10% distortion
30sec each frequency
SCF106
SCF106
EW
Voltage Distortion - Endurance test with motor
10% distortion
Per Table SCF 106-2
SCF106-EW
SCF106
E
Voltage Distortion - Endurance test without
motor
10% distortion
Per Table SCF 106-2
SCF106-E
SCF107
Inrush Current
Test requires multiple load cables
Test not performed with software
SCF108
Frequency Modulation
Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to
100Hz
DO160 16.5.1.3, 400Hz
SCF108
SCF109
Voltage DC Content
+/-.3VDC Offset
30 mins each test
SCF109
SCF110
Voltage Modulation due to Equipment
Test requires special cables
Test not performed with software
SCF111
Voltage Spike Due to Equipment Load
Switching
Requires Additional Equipment
SCF201
Abnormal Steady State Voltage and Frequency
96 to 130 Volts RMS
DO160 16.5.2.1.b, 400Hz
SCF201
SCF202
Abnormal Voltage Transients
Surge to 180Vac max, Sag to 0Vac min
DO160 16.5.2.2.b, 400Hz
SCF202
SCF203
Abnormal Voltage Modulation
Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz
DO160 16.5.1.2, 400Hz
SCF203
SCF204
Abnormal Frequency Variations
320Hz to 480Hz
SCF204
SCF401
Transparency Time
10ms dropouts
Per Figure SCF 401-1
SCF401
SCF402
Voltage Switching Transients 1
Test Conditions 1-17, 400Hz
Per Figure SCF 402-1
SCF402-1
SCF402
Voltage Switching Transients 1
Test Conditions 18-27, 400Hz
Per Figure SCF 402-1
SCF402-2
SCF402
Voltage Switching Transients 1
Test Conditions 28-36, 400Hz
Per Figure SCF 402-1
SCF402-3
SCF402
Voltage Switching Transients 1
Test Conditions 37-42, 400Hz
Per Figure SCF 402-1
SCF402-4
SCF403
Voltage Switching Transients 2
T=1 to T=49, 400Hz
Per Figure SCF 403-1
SCF403-1
SCF403
Voltage Switching Transients 2
T=50 to T=99, 400Hz
Per Figure SCF 403-1
SCF403-2
SCF403
Voltage Switching Transients 2
T=100 to T=200, 400Hz
Per Figure SCF 403-1
SCF403-3
SCF501
Power Failure
Test requires physically removing line cables
Test not performed with software