beautypg.com

Table scf – AMETEK Compact i/iX Series Software Manual User Manual

Page 198

background image

User Manual

– Rev H

California Instruments

Avionics Software

198

TVF501

Power Failure

Test requires physically removing line cables

Test not performed with software

8.4.1.3

Table SCF:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

SCF101

Steady State Voltage and Frequency

104 to 122 Volts RMS

DO160 16.5.1.1.b, 410Hz and
390Hz

SCF101

SCF102

Voltage Transients

Surge to 160Vac max, Sag to 71Vac min

DO160 16.5.1.5.1.b, 400Hz

SCF102

SCF103

Voltage Modulation

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

DO160 16.5.1.2, 400Hz

SCF103

SCF104

Voltage Spikes

Requires Additional Equipment

SCF105

Current Distortion

115Vnom, 400 Hz

Limits defined by Table A.4

SCF105

SCF106

Voltage Distortion

10% distortion

30sec each frequency

SCF106

SCF106

EW

Voltage Distortion - Endurance test with motor

10% distortion

Per Table SCF 106-2

SCF106-EW

SCF106

E

Voltage Distortion - Endurance test without
motor

10% distortion

Per Table SCF 106-2

SCF106-E

SCF107

Inrush Current

Test requires multiple load cables

Test not performed with software

SCF108

Frequency Modulation

Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to
100Hz

DO160 16.5.1.3, 400Hz

SCF108

SCF109

Voltage DC Content

+/-.3VDC Offset

30 mins each test

SCF109

SCF110

Voltage Modulation due to Equipment

Test requires special cables

Test not performed with software

SCF111

Voltage Spike Due to Equipment Load
Switching

Requires Additional Equipment

SCF201

Abnormal Steady State Voltage and Frequency

96 to 130 Volts RMS

DO160 16.5.2.1.b, 400Hz

SCF201

SCF202

Abnormal Voltage Transients

Surge to 180Vac max, Sag to 0Vac min

DO160 16.5.2.2.b, 400Hz

SCF202

SCF203

Abnormal Voltage Modulation

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

DO160 16.5.1.2, 400Hz

SCF203

SCF204

Abnormal Frequency Variations

320Hz to 480Hz

SCF204

SCF401

Transparency Time

10ms dropouts

Per Figure SCF 401-1

SCF401

SCF402

Voltage Switching Transients 1

Test Conditions 1-17, 400Hz

Per Figure SCF 402-1

SCF402-1

SCF402

Voltage Switching Transients 1

Test Conditions 18-27, 400Hz

Per Figure SCF 402-1

SCF402-2

SCF402

Voltage Switching Transients 1

Test Conditions 28-36, 400Hz

Per Figure SCF 402-1

SCF402-3

SCF402

Voltage Switching Transients 1

Test Conditions 37-42, 400Hz

Per Figure SCF 402-1

SCF402-4

SCF403

Voltage Switching Transients 2

T=1 to T=49, 400Hz

Per Figure SCF 403-1

SCF403-1

SCF403

Voltage Switching Transients 2

T=50 to T=99, 400Hz

Per Figure SCF 403-1

SCF403-2

SCF403

Voltage Switching Transients 2

T=100 to T=200, 400Hz

Per Figure SCF 403-1

SCF403-3

SCF501

Power Failure

Test requires physically removing line cables

Test not performed with software