115vac for ground handling equipment – AMETEK Compact i/iX Series Software Manual User Manual
Page 81
User Manual - Rev H
California Instruments
Avionics Software
81
4.4.2.2
115VAC for Ground Handling Equipment:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
1.0
Normal AC Steady State
1.1
Individual Phase Voltage
100.0 to 122.0 Volts RMS
30 mins, 441Hz and 360Hz
GHLVAC-11
1.2
Average of Three-Phase Voltages
101.5 to 120.5 Volts RMS
30 mins, 441Hz and 360Hz
GHLVAC-12
1.3
Phase Displacement
120.0 +/- 4.0°
No specified test
1.4
Phase Voltage Unbalance
Max. 6.0 Volts RMS
Apply each test 30 mins
GHLVAC-14
1.5
AC Voltage Modulation
1.5.1
Maximum Amplitude
5.0 Volts Peak-to-Valley
Follows specification Figure 1
GHLVAC-15
1.5.2
Frequency Components
Per Figure 1
Figure only, not a test. (Refer to spec)
1.6
Voltage Waveform
1.6.1
Total Harmonic Content
Max. 10% of Fundamental
30 mins each test
GHLVAC-16-1
1.6.2
Individual Harmonic Content
Max. 8% of Fundamental
Requires audio generator
1.6.3
DC Content
+/-0.10 Volts (after first cycle)
30 mins each test
GHLVAC-16-3
1.6.4
Crest Factor
1.41 +/- 0.15
No specified test
1.7
Steady State Frequency (see Designer Notes)
360 to 441 Hz
Requirement fulfilled in 1.1 and 1.2
1.8
Frequency Modulation
Applies to Ground Handling Equip only
GHLVAC-18
2.0
Normal AC Transients
2.1
Voltage Transients
50ms Dropouts
441Hz and 360Hz
GHLVAC-21-1
2.1
Voltage Transients
Voltage Surge/Sag
3 times each, 441Hz and 360Hz
GHLVAC-21-2
2.1
Voltage Transients
Per Table B.2.1.1.1
2 times each
GHLVAC-21-3
2.2
Voltage Spikes
Per Figure 10
Requires additional equipment
2.3.1
Frequency Variations - Max Ramp Rate
100Hz/s up, 200Hz/s down
N/A for GHE
2.3.2
Frequency Variations - Frequency Transients
Applies to Ground Handling Equip only
GHLVAC-23
3.0
Abnormal AC Steady State
3.1
Individual Phase Voltage
90.0 to 134.0 Volts RMS
Single Phase Unit Test
GHLVAC-31
3.2
Average of Three-Phase Voltages
91.5 to 132.5 Volts RMS
5 mins each test
GHLVAC-32-1
3.2
Average of Three-Phase Voltages
90.0 to 134.0 Volts RMS
Three Phase Unit Test
GHLVAC-32-2
3.3
Abnormal Steady State Frequency (see Designer Notes)
360 to 441 Hz
Requirement fulfilled in 1.7
4.0
Abnormal AC Transients
4.1
Voltage Transients
Per Figure 5A
Apply each transient 3x with 10s interval
GHLVAC-41
4.2
Frequency Transients
4.2.1
Maximum Ramp Rate
120Hz/s up, 400Hz/s down
N/A for GHE
4.2.2
Frequency Transients
350 to 480 Hz
3 times each, 400Hz nominal
GHLVAC-42-2