beautypg.com

Amd power groups – AMETEK Compact i/iX Series Software Manual User Manual

Page 193

background image

User Manual - Rev H

California Instruments

Avionics Software

193

8.2

–AMD Power Groups

The

–AMD option supports both AC and DC modes of operation. The correct mode is a function of

the EUT to be tested and the operator must select the corresponding operating mode first. This can
be done from the front panel if needed or using the Gui program. Use of the Gui program for all
settings will be assumed for the remainder of this chapter.

Five power groups are covered in the Airbus A400M AMD-24 directive:

Group

Description

SVF

Single Phase 115VAC / Variable Frequency, 390

– 620 Hz.

TVF

Three Phase 115VAC / Variable Frequency, 390

– 620Hz.

SCF

Single Phase 115VAC / 400 Hz

TCF

Three Phase 115VAC / 400 Hz

LDC

28VDC

The required steady state output settings for each power group must be selected based on the type of EUT to
be tested. These settings can be made from the front panel of the power source or from the main Gui control
screen.