beautypg.com

Tvfh – AMETEK Compact i/iX Series Software Manual User Manual

Page 155

background image

User Manual - Rev H

California Instruments

Avionics Software

155

6.3.1.8

TVFH:

#

Test

No.

Subject

Test Limits

DO160 Ref.

Comments

Test File

1

Normal Operation

2

TVFH101

Steady State Voltage and
frequency

202.0V to 243V RMS

16.5.1.1.c.1 (1)

Apply at 360Hz and 900Hz

TVFH101

3

TVFH102

Voltage Transients

136V to 324V RMS

16.5.1.5.b

Appendix A, Table C.4

TVFH102

4

TVFH103

1

Voltage Modulation

206.0V RMS, 360 Hz

16.5.1.5.b

Appendix B, Figure B.2

TVFH103-1

5

TVFH103

2

Voltage Modulation

243.0V RMS, 360 Hz

16.5.1.5.b

Appendix B, Figure B.2

TVFH103-2

6

TVFH103

3

Voltage Modulation

206.0V RMS, 900 Hz

16.5.1.5.b

Appendix B, Figure B.2

TVFH103-3

7

TVFH103

4

Voltage Modulation

243.0V RMS, 900 Hz

16.5.1.5.b

Appendix B, Figure B.2

TVFH103-4

8

TVFH104

Voltage Spikes

184V to 1000V

17.4, Figure 17.4

Not supported, additional equipment
required.

9

TVFH105

Current Distortion

Requires external HF
power analyzer

App A, Tables A.7, A.8, App B, Fig
B.14

TVFH105

10

TVFH106

1

Voltage Distortion 1

Distortion limits

Appendix D

TVFH106-1

11

TVFH106

2

VTHD 1 - No motor

Endurance

Appendix D

TVFH106-2

12

TVFH106

2M

VTHD 1 - EUT incl. motor

Endurance

Appendix D

TVFH106-2M

13

TVFH107

Voltage Distortion 2

700Hz to 150KHz

Section 18, Figure
18-1

Not supported, additional equipment
required.

14

TVFH108

Voltage Distortion Transients

Distortion limits

Appendix D

TVFH108

15

TVFH109

Inrush current

200V to 260V RMS

App B, Figure B.18,B19

TVFH109

16

TVFH110

Frequency Variations

360Hz to 900Hz,
100Hz/s

Appendix A, Table A.4

TVFH110

17

TVFH111

Frequency Modulation

360Hz and 900Hz

Appendix B, Figure B.10

TVFH111

18

TVFH112

Voltage DC Content

-0.3Vdc and +0.3Vdc

Appendix B, Figure B.17

TVFH112

19

TVFH113

VMod due to equipment.

200V to 260V, 360Hz
and 900Hz

App A, Table A.3, App B, Fig B.2

TVFH113

20

TVFH114

VSpike due to equipment.

230V, 360Hz and 900Hz

App B, Fig 4. Requires external
contactors

TVFH114

21

TVFH115

Voltage unbalance transient

202V to 248V, 360Hz
and 900Hz

App A, Table A.4

TVFH115

22

Abnormal Operation

23

TVFH201

Steady State Voltage and
Frequency

192V to 260V, 360Hz
and 900Hz

16.5.2.1.c

Appendix A, Table A.3

TVFH201

24

TVFH202

Voltage Transients

0V to 360V, 360Hz and
900Hz

16.5.2.2.b &
16.5.2.2.b

Appendix A, Table A.4

TVFH202