AMETEK Compact i/iX Series Software Manual User Manual
Page 132

User Manual
– Rev H
California Instruments
132
Avionics Software
Variable Frequency A350 Power Groups
– 3001/5001iX Series.
AC Power Groups
No.
Description
SVF
TVF
SVFH
TVFH
Normal Operation
9003/15003
101
Steady-state voltage and frequency
YES
YES
X
X
102
Voltage transients
YES
YES
X
X
103
Voltage modulation
YES
YES
X
X
104
Voltage spikes
X
X
X
X
105
Current distortion
YES
YES
X
X
106
Voltage distortion 1
P
P
X
X
107
Voltage distortion 2
X
X
X
X
108
Voltage distortion transients
P
P
X
X
109
Inrush current
YES
YES
X
X
110
Frequency variations
YES
YES
X
X
111
Frequency modulation
YES
YES
X
X
112
Voltage DC content
P
P
X
X
113
Voltage modulation due to equipment
YES
YES
X
X
114
Voltage spike due to equipment load switching
YES
YES
X
X
115
Voltage unbalance transient
N/A
YES
X
X
Abnormal Operation
9003/15003
201
Steady-state voltage and frequency
YES
YES
X
X
202
Voltage transients
YES
YES
X
X
203
Voltage modulation
YES
YES
X
X
Emergency Operation
9003/15003
301
Steady-state voltage and frequency
YES
YES
X
X
302
Voltage distortion 1
YES
YES
X
X
303
Voltage distortion 2
YES
YES
X
X
304
Voltage distortion transients
YES
YES
X
X
305
Inrush current
YES
YES
X
X
306
Frequency variations
YES
YES
X
X
307
Voltage modulation due to equipment
YES
YES
X
X
Switching Transients
9003/15003
401
Transparency time
YES
YES
X
X
402
Voltage switching transients 1
(1)
(1)
X
X
403
Voltage switching transients 2
(1)
(1)
X
X
404
Voltage switching transients with frequency change
YES
YES
X
X
Power Supply Removal
9003/15003
501
Power line disconnection
YES
YES
X
X
Note (1): Provided through ABD Switching Transients test menu.