beautypg.com

I/ix series –a350 option limitations – AMETEK Compact i/iX Series Software Manual User Manual

Page 131

background image

User Manual - Rev H

California Instruments

Avionics Software

131

6.1.2

i/iX Series

–A350 Option Limitations

The extent of coverage of the

–A350 option as implemented on the i/iX Series and Compact i/iX

Series platforms is shown in the table below. Tests marked with an „X‟ generally require additional
hardware to be used. Tests marked with a „P‟ require arbitrary waveform capability, which is available
on iX models only.

Section 6.2.1.4 and Appendix D current harmonics measurements will require the use of an external
power analyzer per Figure B.14 of ABD0100.1.8.1 since the iX Series measurement system does not
support the required measurement bandwidth for this test.

The following variable frequency power groups are not supported on the 3001/5001i/iX series due to
voltage/frequency output restrictions: SVFH, TVFH. They are supported on the compact i/iX Series
however.

The following tests from the SVFH, TVFH, SCFH and TCFH power groups are not supported, as they
require more than 300Vrms output voltage: 102, 202.

The Compact i/iX Series does not support CF112 and VF112 DC offset test due to offset
programming accuracy restrictions. An external DC offset supply is required to perform these tests
per Figure B.16 and B.17 of the test standard.