Table e – AMETEK Compact i/iX Series Software Manual User Manual
Page 185
User Manual - Rev H
California Instruments
Avionics Software
185
7.4.2.5
Table E:
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
1
2
1.1
Maximum Voltage - Norm and Emer
32V DC
16.5.2.1.b (1)
E1P0_NORM_MAXV
3
1.2
24V DC
16.5.2.1.b (2)
E1P0_NORM_MINV
4
1.3
Minimum voltage - Emergency
operation
18.5V DC
16.5.2.1.b (3)
E1P0_EMER_MINV
5
2
Voltage Surge - Figure 13
6
2.1
Normal Transients
36V for 100ms
16.5.2.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE1
7
2.2
Normal Transients
35V for 200ms
16.5.2.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE2
8
2.3
Normal Transients
34V for 300ms
16.5.2.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE3
9
2.4
Normal Transients
18.5V for 5 secs
16.5.2.4.b
Use specified limit iso DO160
E2P0_NORMVSURGE4
10
3
Voltage Surge - Figure 13
11
3.1
Abnormal Transients
36V for 1 sec
16.5.4.4.c
Apply also Appendix 3 test
E3P0_ABNVSURGE1
12
3.2
Abnormal Transients
33V for 3 sec
16.5.4.4.c
Apply also Appendix 3 test
E3P0_ABNVSURGE2
13
3.3
Abnormal Transients
0V for 5 secs
16.5.4.3.b
Apply also Appendix 3 test
E3P0_ABNVSURGE3
14
3.4
Abnormal Transients
Disconnects for 5
secs
n/a
Appendix 3 tests for multiple power
input equipment.
E3P3_APPENDIX3
15
4
Voltage Spikes - Fig 3-C
Peak voltage 600V
17.4
Requires additional equipment
16
5
Switching Transients
Appendix 1
n./a
Appendix 1 DC Switching Transients
17
5.1
Cf Figure A
Table 1.2 - T1 >= 3
msec
n./a
E5P0_APP1TransientsA
18
5.2.1
Cf Figure B
Table 1.2 - N=1
n./a
E5P0_APP1TransientsB_N1
19
5.2.2
Cf Figure B
Table 1.2 - N=2
n./a
E5P0_APP1TransientsB_N2
20
5.2.3
Cf Figure B
Table 1.2 - N=3
n./a
E5P0_APP1TransientsB_N3
21
5.2.4
Table 1.2 - N=4
n./a
E5P0_APP1TransientsB_N4
22
5.2.5
Cf Figure B
Table 1.2 - N=5
n./a
E5P0_APP1TransientsB_N5
23
6
Ripple Voltage
Figure 8
16.5.2.2 and Figure 18.2
Requires additional equipment
24
7
Starting inrush current
Figure 14
n/a
Refer to ABD0100.1.8 par 2.4.2.3.2.2
E7P0_DCINRUSH