Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual
Page 51
User Manual - Rev H
California Instruments
Avionics Software
51
3.4.2.6
Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b Voltage (Average Value dc)
22.0V to 30.3V
Apply for 30 mins each test
FZDC28_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3) Voltage (Average Value dc)
18.0V
Apply for 30 mins each test
FZDC28_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = 0.6V to 1.6V, Freq = 10Hz to 200Hz Figure 18-2
FZDC28_VRIP
16.6.1.3b Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
FZDC28_PINTB
16.6.1.3c Momentary Power Interruptions (dc)
Other Equipment
FZDC28_PINTC
16.6.1.4 Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
50V to 12V
FZDC28_NVSUR
16.6.1.5 Engine Starting Under Voltage Operation (dc) 10V min
Slew for 35 sec
FZDC28_VENG
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1 Voltage Steady State (dc)
20.5V to 32.2V
Apply for 5 mins each test
FZDC28_VABN
16.6.2.3 Momentary Undervoltage (dc)
12V
Apply for 7 seconds each test
FZDC28_VUND
16.6.2.4 Abnormal Transients (ac)
16.6.2.4b - Abnormal Voltage Surge
80VDC
Figure 16-4 - apply at 10 sec intervals FZDC28_AVSUR
3.4.2.7
Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.5.1
Normal Operating Conditions (ac)
16.5.1.1b(1) 1 Phs Voltage and Frequency (ac)
200V to 244V, 390Hz to 410Hz
Apply for 30 mins each test
FACF230_VFNORM1P
16.5.1.1c(1) 3 Phs Voltage and Frequency (ac)
200V to 244V, 390Hz to 410Hz
Apply for 30 mins each test
FACF230_VFNORM3P
16.5.1
Emergency Operating Conditions (ac)
16.5.1.1b(2) 1 Phs Voltage and Frequency (ac)
200V to 244V, 360Hz to 440Hz
Apply for 30 mins each test
FACF230_VFEMER1P
16.5.1.1c(2) 3 Phs Voltage and Frequency (ac)
200V to 244V, 360Hz to 440Hz
Apply for 30 mins each test
FACF230_VFEMER3P
16.5.1
Normal Operating Conditions (ac)
16.5.1.2 Voltage Modulation (ac)
Vamp = 0.36V to 2.48V, Mrate = 1Hz to 200Hz
Figure 16-1
FACF230_VMOD
16.5.1.3 Frequency Modulation (ac)
Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to 100Hz Figure 16-2
FACF230_FMOD
16.5.1.4b Momentary Power Interruptions (ac)
Table 16-1
Equipment with Digital Circuits
FACF230_PINTB
16.5.1.4c Momentary Power Interruptions (ac)
Other Equipment
FACF230_PINTC
16.5.1.5 Normal Transients (ac)
1
For more comprehensive DC Ripple tests, refer to section 3.3.