197

TVF110

Voltage DC Content

+/-.3VDC Offset

30 mins each test

TVF110

TVF111

Voltage Modulation due to Equipment

Test requires special cables

Test not performed with software

TVF112

Voltage Spike Due to Equipment Load Switching

Requires Additional Equipment

TVF201

Abnormal Steady State Voltage and Frequency

96 to 130 Volts RMS

DO160 16.5.2.1.b, 620Hz and
390Hz

TVF201

TVF202

Abnormal Voltage Transients

Surge to 180Vac max, Sag to 0Vac min

DO160 16.5.2.2.b, 620Hz and
390Hz

TVF202

TVF203

Abnormal Voltage Modulation

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

DO160 16.5.1.2, 620Hz and 390Hz

TVF203

TVF301

Emergency Steady State Voltage and Frequency

104 to 122 Volts RMS

DO160 16.5.1.1.b, 620Hz and
390Hz

TVF301

TVF302

Emergency Voltage Distortion

15% distortion

30sec each frequency

TVF302

TVF302

EW

Voltage Distortion - Endurance test with motor

15% distortion

Per Table TVF 302-2

TVF302-EW

TVF302

E

Voltage Distortion - Endurance test without motor

15% distortion

Per Table TVF 302-2

TVF302-E

TVF303

Emergency Voltage Distortion Transients

25% distortion

10 times each test

TVF303

TVF304

Emergency Frequency Variations

Slew from 390 to 620Hz, 500Hz/s up and down

3 times each

TVF304

TVF305

Emergency Voltage Modulation due to Equipment

Test requires special cables

Test not performed with software

TVF401

Transparency Time

10ms dropouts

Per Figure TVF 401-1

TVF401

TVF402

Voltage Switching Transients 1

Test Conditions 1-17, 390Hz

Per Figure TVF 402-1

TVF402-1

TVF402

Voltage Switching Transients 1

Test Conditions 18-27, 390Hz

Per Figure TVF 402-1

TVF402-2

TVF402

Voltage Switching Transients 1

Test Conditions 28-36, 390Hz

Per Figure TVF 402-1

TVF402-3

TVF402

Voltage Switching Transients 1

Test Conditions 37-42, 390Hz

Per Figure TVF 402-1

TVF402-4

TVF402

Voltage Switching Transients 1

Test Conditions 1-17, 620Hz

Per Figure TVF 402-1

TVF402-5

TVF402

Voltage Switching Transients 1

Test Conditions 18-27, 620Hz

Per Figure TVF 402-1

TVF402-6

TVF402

Voltage Switching Transients 1

Test Conditions 28-36, 620Hz

Per Figure TVF 402-1

TVF402-7

TVF402

Voltage Switching Transients 1

Test Conditions 37-42, 620Hz

Per Figure TVF 402-1

TVF402-8

TVF403

Voltage Switching Transients 2

T=1 to T=49, 620Hz

Per Figure TVF 403-1

TVF403-1

TVF403

Voltage Switching Transients 2

T=50 to T=99, 620Hz

Per Figure TVF 403-1

TVF403-2

TVF403

Voltage Switching Transients 2

T=100 to T=200, 620Hz

Per Figure TVF 403-1

TVF403-3

TVF403

Voltage Switching Transients 2

T=1 to T=49, 390Hz

Per Figure TVF 403-1

TVF403-4

TVF403

Voltage Switching Transients 2

T=50 to T=99, 390Hz

Per Figure TVF 403-1

TVF403-5

TVF403

Voltage Switching Transients 2

T=100 to T=200, 390Hz

Per Figure TVF 403-1

TVF403-6

TVF404

Voltage Switching Transients with Frequency
Change

50-200ms dropouts

Per Figure TVF 404-1

TVF404