AMETEK Compact i/iX Series Software Manual User Manual
Page 174
User Manual
– Rev H
California Instruments
Avionics Software
174
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
7
2.2
Minimum
23.5V DC
16.6.2.1.b (2)
Apply for 30 mins iso 5 mins
D2P0_ABN_MINV
8
3
Voltage Surge - Fig 2
9
3.1
Normal Transients
40V for 30ms,17V for
15ms
16.6.1.4.b
Replace DO160 28V with 28.8V
D3P0_NORMVSURGE1
10
3.2
Normal Transients
39V for 50ms,19.5V
for 30ms
16.6.1.4.b
Replace DO160 28V with 28.8V
D3P0_NORMVSURGE2
11
3.3
Normal Transients
37V for 100ms,21V for
50ms
16.6.1.4.b
Replace DO160 28V with 28.8V
D3P0_NORMVSURGE3
12
3.4
Normal Transients
35V for 200ms,23,5V
100ms
16.6.1.4.b
Replace DO160 28V with 28.8V
D3P0_NORMVSURGE4
13
4
Voltage Surge - Fig 2
14
4.1
Abnormal Transients
46V for 100ms, 38V
for 1 sec
16.6.2.4.c
Apply also Appendix 3 test
D4P0_ABNVSURGE1
15
4.2
Abnormal Transients
0V for 5 secs
16.6.2.3.b
Apply also Appendix 3 test
D4P0_ABNVSURGE2
16
4.3
Abnormal Transients
Disconnects for 5
secs
n/a
Appendix 3 tests for multiple power
input equipment.
D4P3_APPENDIX3
17
5
Voltage Spike - Fig 3-C
Peak voltage 600V
17.4
Requires additional equipment
18
6
Switching Transients
Appendix 1
n./a
Appendix 1 DC Switching Transients
19
6.1
Cf Figure 1.1
Table 1.1 - T1 1 to 50
msec
n./a
D6P0_APP1A_DC61
20
6.2
Cf Figure 1.1
Table 1.1 - T1 51 to
100 msec
n./a
D6P0_APP1A_DC62
21
6.3
Table 1.1 - T1 100 to
200 msec
n./a
D6P0_APP1A_DC63
22
6.2.1
Cf Figure 1.2
Table 1.1 - N=1
n./a
D6P0_APP1TransientsB_N1
23
6.2.2
Cf Figure 1.2
Table 1.1 - N=2
n./a
D6P0_APP1TransientsB_N2
24
6.2.3
Cf Figure 1.2
Table 1.1 - N=3
n./a
D6P0_APP1TransientsB_N3
25
6.2.4
Cf Figure 1.2
Table 1.1 - N=4
n./a
D6P0_APP1TransientsB_N4
26
6.2.5
Cf Figure 1.2
Table 1.1 - N=5
n./a
D6P0_APP1TransientsB_N5
27
6.2.6
Cf Figure 1.2
Table 1.1 - N=6
n./a
D6P0_APP1TransientsB_N6
28
6.2.7
Cf Figure 1.2
Table 1.1 - N=7
n./a
D6P0_APP1TransientsB_N7
29
6.2.8
Table 1.1 - N=8
n./a
D6P0_APP1TransientsB_N8
30
6.2.9
Cf Figure 1.2
Table 1.1 - N=9
n./a
D6P0_APP1TransientsB_N9
31
6.2.10
Cf Figure 1.2
Table 1.1 - N=10
n./a
D6P0_APP1TransientsB_N1
0
32
6.2.11
Cf Figure 1.2
Table 1.1 - N=11
n./a
D6P0_APP1TransientsB_N1
1