Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual
Page 52
User Manual
– Rev H
California Instruments
52
Avionics Software
16.5.1.5.1 - Normal Voltage Surge (ac)
320V to 140V, 400 Hz
FACF230_NVSUR
16.5.1.5.2 - Normal Frequency Surge (ac) 230V, 350Hz to 400Hz
FACF230_NFSUR
16.5.1.7 Voltage DC Content (ac)
16.5.1.7 - 1 Phs Voltage DC Content (ac)
± 0.2VDC
Apply for 30 mins each test
FACF230_DCOFS1P
16.5.1.7 - 3 Phs Voltage DC Content (ac)
± 0.2VDC
Apply for 30 mins each test
FACF230_DCOFS3P
16.5.1.8 Voltage Distortion (ac)
8% +2%/-0% VTHD - Clipped Sine, 400Hz
Apply for 30 mins each test
FACF230_VTHD
16.5.2
Abnormal Operating Conditions (ac)
16.5.2.1b 1 Phs Voltage (ac)
194V to 268V, 400Hz
Apply for 5 mins each test
FACF230_VABN1P
16.5.2.1c 3 Phs Voltage (ac)
194V to 268V, 400Hz
Apply for 5 mins each test
FACF230_VABN3P
16.5.2.1d 1 Phs Voltage and Frequency (ac)
200V to 244V, 370Hz to 430Hz
Apply for 5 mins each test
FACF230_VFABN1P
16.5.2.1e 3 Phs Voltage and Frequency (ac)
200V to 244V, 370Hz to 430Hz
Apply for 5 mins each test
FACF230_VFABN3P
16.5.2.2 Momentary Undervoltage (ac)
20V and 120V, 400Hz
Apply for 7 seconds each test
FACF230_VUND
16.5.2.3 Abnormal Transients (ac)
16.5.2.3.1 - Abnormal Voltage surge
296V to 360V, 400Hz
Figure 16.5 - apply at 10 sec intervals FACF230_AVSUR
16.5.2.3.1 - Abnormal Frequency transients 0V to 230V, 320Hz to 480Hz
Figure 16.5 - apply at 10 sec intervals FACF230_AFSUR
3.4.2.8
Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b Voltage (Average Value dc)
11.0V to 15.2V
Apply for 30 mins each test
FADC14_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3) Voltage (Average Value dc)
9.0V
Apply for 30 mins each test
FADC14_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = 0.3V to .8V, Freq = 10Hz to 200Hz
Figure 18-2
FADC14_VRIP
16.6.1.3b Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
FADC14_PINTB
16.6.1.3c Momentary Power Interruptions (dc)
Other Equipment
FADC14_PINTC
16.6.1.4
Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
23.5V to 8.5V
FADC14_NVSUR
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1
Voltage Steady State (dc)
10.3V to 16.1V
Apply for 5 mins each test
FADC14_VABN
16.6.2.3
Momentary Undervoltage (dc)
6V
Apply for 7 seconds each test
FADC14_VUND
16.6.2.4
Abnormal Transients (ac)
16.6.2.4c - Abnormal Voltage Surge
23.2V
Figure 16-4 - apply at 10 sec
intervals
FADC14_AVSUR
1
For more comprehensive DC Ripple tests, refer to section 3.3.