Do160 section 16, rev e, Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual
Page 34
User Manual
– Rev H
California Instruments
34
Avionics Software
3.4.1
DO160 Section 16, Rev E:
3.4.1.1
Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.5.1
Normal Operating Conditions (ac)
16.5.1.1b(1) 1 Phs Voltage and Frequency (ac)
100V to 122V, 390Hz to 410Hz
Apply for 30 mins each test
EACF115_VFNORM1P
16.5.1.1c(1) 3 Phs Voltage and Frequency (ac)
100V to 122V, 390Hz to 410Hz
Apply for 30 mins each test
EACF115_VFNORM3P
16.5.1
Emergency Operating Conditions (ac)
16.5.1.1b(2) 1 Phs Voltage and Frequency (ac)
100V to 122V, 360Hz to 440Hz
Apply for 30 mins each test
EACF115_VFEMER1P
16.5.1.1c(2) 3 Phs Voltage and Frequency (ac)
100V to 122V, 360Hz to 440Hz
Apply for 30 mins each test
EACF115_VFEMER3P
16.5.1
Normal Operating Conditions (ac)
16.5.1.2
Voltage Modulation (ac)
Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz
Figure 16-1
EACF115_VMOD
16.5.1.3
Frequency Modulation (ac)
Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to 100Hz Figure 16-2
EACF115_FMOD
16.5.1.4b
Momentary Power Interruptions (ac)
Table 16-1
Equipment with Digital Circuits EACF115_PINTB
16.5.1.4c
Momentary Power Interruptions (ac)
Other Equipment
EACF115_PINTC
16.5.1.5
Normal Transients (ac)
16.5.1.5.1 - Normal Voltage Surge (ac)
160V to 70V, 400 Hz
EACF115_NVSUR
16.5.1.5.2 - Normal Frequency Surge (ac)
115V, 350Hz to 400Hz
EACF115_NFSUR
16.5.1.7
Voltage DC Content (ac)
16.5.1.7 - 1 Phs Voltage DC Content (ac)
± 0.1VDC
Apply for 30 mins each test
EACF115_DCOFS1P
16.5.1.7 - 3 Phs Voltage DC Content (ac)
± 0.1VDC
Apply for 30 mins each test
EACF115_DCOFS3P
16.5.1.8
Voltage Distortion (ac)
8% +2%/-0% VTHD - Clipped Sine, 400Hz
Apply for 30 mins each test
EACF115_VTHD
16.5.2
Abnormal Operating Conditions (ac)
16.5.2.1b
1 Phs Voltage (ac)
97V to 134V, 400Hz
Apply for 5 mins each test
EACF115_VABN1P
16.5.2.1c
3 Phs Voltage (ac)
97V to 134V, 400Hz
Apply for 5 mins each test
EACF115_VABN3P
16.5.2.1d
1 Phs Voltage and Frequency (ac)
100V to 122V, 370Hz to 430Hz
Apply for 5 mins each test
EACF115_VFABN1P
16.5.2.1e
3 Phs Voltage and Frequency (ac)
100V to 122V, 370Hz to 430Hz
Apply for 5 mins each test
EACF115_VFABN3P
16.5.2.2
Momentary Undervoltage (ac)
10V and 60V, 400Hz
Apply for 7 seconds each test
EACF115_VUND
16.5.2.3
Abnormal Transients (ac)
16.5.2.3.1 - Abnormal Voltage surge
148V to 180V, 400Hz
Figure 16.5 - apply at 10 sec
intervals
EACF115_AVSUR
16.5.2.3.1 - Abnormal Frequency transients 0V to 115V, 320Hz to 480Hz
Figure 16.5 - apply at 10 sec
intervals
EACF115_AFSUR