beautypg.com

Do160 section 16, rev e, Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual

Page 34

background image

User Manual

– Rev H

California Instruments

34

Avionics Software

3.4.1

DO160 Section 16, Rev E:

3.4.1.1

Table A(CF)115:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

16.5.1

Normal Operating Conditions (ac)

16.5.1.1b(1) 1 Phs Voltage and Frequency (ac)

100V to 122V, 390Hz to 410Hz

Apply for 30 mins each test

EACF115_VFNORM1P

16.5.1.1c(1) 3 Phs Voltage and Frequency (ac)

100V to 122V, 390Hz to 410Hz

Apply for 30 mins each test

EACF115_VFNORM3P

16.5.1

Emergency Operating Conditions (ac)

16.5.1.1b(2) 1 Phs Voltage and Frequency (ac)

100V to 122V, 360Hz to 440Hz

Apply for 30 mins each test

EACF115_VFEMER1P

16.5.1.1c(2) 3 Phs Voltage and Frequency (ac)

100V to 122V, 360Hz to 440Hz

Apply for 30 mins each test

EACF115_VFEMER3P

16.5.1

Normal Operating Conditions (ac)

16.5.1.2

Voltage Modulation (ac)

Vamp = 0.18V to 1.24V, Mrate = 1Hz to 200Hz

Figure 16-1

EACF115_VMOD

16.5.1.3

Frequency Modulation (ac)

Famp = 4.9 Hz to 0.2Hz, Mrate = 0.014Hz to 100Hz Figure 16-2

EACF115_FMOD

16.5.1.4b

Momentary Power Interruptions (ac)

Table 16-1

Equipment with Digital Circuits EACF115_PINTB

16.5.1.4c

Momentary Power Interruptions (ac)

Other Equipment

EACF115_PINTC

16.5.1.5

Normal Transients (ac)

16.5.1.5.1 - Normal Voltage Surge (ac)

160V to 70V, 400 Hz

EACF115_NVSUR

16.5.1.5.2 - Normal Frequency Surge (ac)

115V, 350Hz to 400Hz

EACF115_NFSUR

16.5.1.7

Voltage DC Content (ac)

16.5.1.7 - 1 Phs Voltage DC Content (ac)

± 0.1VDC

Apply for 30 mins each test

EACF115_DCOFS1P

16.5.1.7 - 3 Phs Voltage DC Content (ac)

± 0.1VDC

Apply for 30 mins each test

EACF115_DCOFS3P

16.5.1.8

Voltage Distortion (ac)

8% +2%/-0% VTHD - Clipped Sine, 400Hz

Apply for 30 mins each test

EACF115_VTHD

16.5.2

Abnormal Operating Conditions (ac)

16.5.2.1b

1 Phs Voltage (ac)

97V to 134V, 400Hz

Apply for 5 mins each test

EACF115_VABN1P

16.5.2.1c

3 Phs Voltage (ac)

97V to 134V, 400Hz

Apply for 5 mins each test

EACF115_VABN3P

16.5.2.1d

1 Phs Voltage and Frequency (ac)

100V to 122V, 370Hz to 430Hz

Apply for 5 mins each test

EACF115_VFABN1P

16.5.2.1e

3 Phs Voltage and Frequency (ac)

100V to 122V, 370Hz to 430Hz

Apply for 5 mins each test

EACF115_VFABN3P

16.5.2.2

Momentary Undervoltage (ac)

10V and 60V, 400Hz

Apply for 7 seconds each test

EACF115_VUND

16.5.2.3

Abnormal Transients (ac)

16.5.2.3.1 - Abnormal Voltage surge

148V to 180V, 400Hz

Figure 16.5 - apply at 10 sec
intervals

EACF115_AVSUR

16.5.2.3.1 - Abnormal Frequency transients 0V to 115V, 320Hz to 480Hz

Figure 16.5 - apply at 10 sec
intervals

EACF115_AFSUR