beautypg.com

Table adc14 – AMETEK Compact i/iX Series Software Manual User Manual

Page 43

background image

User Manual - Rev H

California Instruments

Avionics Software

43

3.4.1.8

Table ADC14:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

16.6.1

Normal Operating Conditions (dc)

16.6.1.1b Voltage (Average Value dc)

11.0V to 15.2V

Apply for 30 mins each test

EADC14_VAVG

16.6.1

Emergency Operating Conditions (dc)

16.6.1.1b(3) Voltage (Average Value dc)

9.0V

Apply for 30 mins each test

EADC14_VAVGEMER

16.6.1

Normal Operating Conditions (dc)

16.6.1.2

1

Ripple Voltage (dc)

Vp-p = 0.3V to .8V, Freq = 10Hz to 200Hz

Figure 18-2

EADC14_VRIP

16.6.1.3b Momentary Power Interruptions (dc)

Table 16-3

Equipment with Digital Circuits

EADC14_PINTB

16.6.1.3c Momentary Power Interruptions (dc)

Other Equipment

EADC14_PINTC

16.6.1.4

Normal Transients (dc)

16.6.1.4b - Normal Voltage Surge (dc)

23.5V to 8.5V

EADC14_NVSUR

16.6.2

Abnormal Operating Conditions (dc)

16.6.2.1

Voltage Steady State (dc)

10.3V to 16.1V

Apply for 5 mins each test

EADC14_VABN

16.6.2.3

Momentary Undervoltage (dc)

6V

Apply for 7 seconds each test

EADC14_VUND

16.6.2.4

Abnormal Transients (ac)

16.6.2.4c - Abnormal Voltage Surge

23.2V

Figure 16-4 - apply at 10 sec
intervals

EADC14_AVSUR

1

For more comprehensive DC Ripple tests, refer to section 3.3.