Avionics Software

4.2

Frequency Transients

4.2.1

Maximum Ramp Rate

100Hz/s up, 200Hz/s down

Test procedure TBD

4.2.2

Transients Outside of Steady State Range

Per Figure 6

Test procedure TBD

4.3

DC Content

Per Figure 11

Test procedure TBD

SUPP

Supplementary Transient Test Requirements

Tests 1-7, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-1

SUPP

Supplementary Transient Test Requirements

Tests 8-14, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-2

SUPP

Supplementary Transient Test Requirements

Tests 15-20, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-3

SUPP

Supplementary Transient Test Requirements

Tests 21-27, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-4

SUPP

Supplementary Transient Test Requirements

Tests 28-34, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-5

SUPP

Supplementary Transient Test Requirements

Tests 35-40, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-6

SUPP

Supplementary Transient Test Requirements

Tests 41-47, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-7

SUPP

Supplementary Transient Test Requirements

Tests 48-53, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-8

SUPP

Supplementary Transient Test Requirements

Tests 54-62, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-9

SUPP

Supplementary Transient Test Requirements

Tests 63-74, Table 3.3.2-3A

Tests performed at 360, 530, and 800 Hz

LSUPP-10

SUPP

Supplementary Transient Test Requirements

Tests 1-6 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

LSUPP-11

SUPP

Supplementary Transient Test Requirements

Tests 7-12 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

LSUPP-12

SUPP

Supplementary Transient Test Requirements

Tests 13-15 Table 3.3.2-3B

Tests performed at 360, 530, and 800 Hz

LSUPP-13

4.4.3.2

230VAC:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

1.0

Normal AC Steady State

1.1

Individual Phase Voltage

190.0 to 244.0 Volts RMS

30 mins, 800Hz and 360Hz

HVAC-11

1.2

Average of Three-Phase Voltages

193.0 to 241.0 Volts RMS

30 mins, 800Hz and 360Hz

HVAC-12

1.3

Phase Displacement

120.0 +/- 4.0°

Apply from main gui screen manually

1.4

Phase Voltage Unbalance

Max. 12.0 Volts RMS

Apply each test 30 mins

HVAC-14

1.5

AC Voltage Modulation

1.5.1

Maximum Amplitude

10.0 Volts Peak-to-Valley

Follows specification Figure 1

HVAC-15

1.5.2

Frequency Components

Per Figure 1

Figure only, not a test. (Refer to spec)

1.6

Voltage Waveform

1.6.1

Total Harmonic Content

Max. 10% of Fundamental

30 mins each test

HVAC-16-1

1.6.2

Individual Harmonic Content

Max. 8% of Fundamental

Requires audio generator

1.6.3

DC Content

+/-0.20 Volts (after first cycle)

30 mins each test

HVAC-16-2

1.6.4

Crest Factor

1.41 +/- 0.15