Avionics Software

6.2

–A350 Power Groups

The

–A350 option supports both AC and DC modes of operation. The correct mode is a function of

the EUT to be tested and the operator must select the corresponding operating mode first. This can
be done from the front panel if needed or using the Gui program. Use of the Gui program for all
settings will be assumed for the remainder of this chapter.

Nine power groups are covered in the ABD0100.1.8.1 A350 directive:

Group

Description

SVF

AC, Single phase, 115VAC, Variable frequency.

SVFH

AC, Single phase, 230VAC, Variable frequency.

SCF

AC, Single phase, 115VAC, Constant frequency.

SCFH

AC, Single phase, 230VAC, Constant frequency.

TVF

AC, Three phase, 115VAC, Variable frequency.

TVFH

AC, Three phase, 230VAC, Variable frequency.

TCF

AC, Three phase, 115VAC, Constant frequency.

TCFH

AC, Three phase, 230VAC, Constant frequency.

LDC

DC 28VDC

The required steady state output settings for each power group must be selected based on the type of
EUT to be tested. These settings can be made from the front panel of the power source or from the
main Gui control screen.

6.3 Test Tables


The tables shown on the next few pages list the test sections covered by the

–A350 option. Where

relevant, the numbering used matches that of the ABD0100.1.8.1 document. The notes in the right
hand column indicate tests that are either not directly supported or require additional external test
equipment. Test tables are listed by rev and then by power group. The list starts with the most current
rev to date, rev B.

Data shown is for MX Series. Other models may have slight variations from the data shown here.