beautypg.com

Table hdc, Rev e, Rev d – AMETEK Compact i/iX Series Software Manual User Manual

Page 115

background image

User Manual - Rev H

California Instruments

Avionics Software

115

Test No. Section

Subject

Test Limits

Comment

File Ref.

LDC602

Polarity Reversal

Polarity reversal done physically FLDC602

5.3.1.7

Table HDC:

Test No. Section

Subject

Test Limits

Comment

File Ref.

HDC101

Load Measurements

270V DC

FHDC101

HDC102

Steady State Limits for Voltage

250V to 280V DC

Apply for 30 mins

FHDC102

HDC103

Voltage Distortion Spectrum

Requires Additional Equipment

HDC104

Total Ripple

Requires Additional Equipment

HDC105

Normal Voltage Transients

200V to 330V DC

1

Overvoltage Transients

Peak Voltage 330V DC

Table HDC105-2 AA-JJ

FHDC105-1

2

Undervoltage Transients

Low Voltage 200V DC

Table HDC105-2 KK-PP

FHDC105-2

3

Combined Transients

200V to 330V DC

Table HDC105-2 QQ-RR

FHDC105-3

4

Repetitive Normal Voltage Transient Test

215V to 315V DC

Repeat transient for 30 mins

FHDC105-4

HDC201

Power Interrupt

0V for 50 msec

Table HDC201-2 A-L

FHDC201

HDC301

Abnormal Steady State Limits for Voltage

240V to 290V DC

Apply each test for 30 mins

FHDC301

HDC302

Abnormal Voltage Transients

180V to 350V DC

1

Overvoltage Transients

Peak Voltage 350V DC

Table HDC302-4 AAA-FFF

FHDC302-1

2

Undervoltage Transients

Low Voltage 180V DC

Table HDC302-4 GGG-LLL

FHDC302-2

3

Combined Transients

180V to 350V DC

Table HDC302-4 MMM-NNN

FHDC302-3

HDC401

Emergency Limits for Voltage

250V to 280V DC

Apply each test for 30 mins

FHDC401

HDC501

Starting Voltage Transients

115V to 280V DC

Table HDC501-3 AA

FHDC501

HDC601

Power Failure

0V for 7 seconds

Table HDC601-2 A-D

FHDC601

HDC602

Polarity Reversal

Polarity reversal done physically

FHDC602

5.3.2

Rev E

This test should be performed using the firmware version of the

–704 option.

5.3.3

Rev D

This test should be performed using the firmware version of the

–704 option.