beautypg.com

AMETEK Compact i/iX Series Software Manual User Manual

Page 110

background image

User Manual

– Rev H

California Instruments

110

Avionics Software

Test No. Section

Subject

Test Limits

Comment

File Ref.

360-2 360 Hz, Undervoltage Transients

Low Voltage 80V RMS

Table SVF109-2

FSVF109-360-2

360-3 360 Hz, Combined Transient

180V to 80V RMS

Table SVF109-2

FSVF109-360-3

360-4 360 Hz, Repetitive Normal Voltage Transient Test

90V to 140V RMS

Figure SVF109-2

FSVF109-360-4

600-1 600 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF109-2

FSVF109-600-1

600-2 600 Hz, Undervoltage Transients

Low Voltage 80V RMS

Table SVF109-2

FSVF109-600-2

600-3 600 Hz, Combined Transient

180V to 80V RMS

Table SVF109-2

FSVF109-600-3

600-4 600 Hz, Repetitive Normal Voltage Transient Test

90V to 140V RMS

Figure SVF109-2

FSVF109-600-4

800-1 800 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF109-2

FSVF109-800-1

800-2 800 Hz, Undervoltage Transients

Low Voltage 80V RMS

Table SVF109-2

FSVF109-800-2

800-3 800 Hz, Combined Transient

180V to 80V RMS

Table SVF109-2

FSVF109-800-3

800-4 800 Hz, Repetitive Normal Voltage Transient Test

90V to 140V RMS

Figure SVF109-2

FSVF109-800-4

SVF110

Normal Frequency Transients

1

Overfrequency Transients

High Frequency 800 Hz

Table SVF110-2

FSVF110-1

2

Underfrequency Transients

Low Frequency 360 Hz

Table SVF110-2

FSVF110-2

3

Combined Transient

360 Hz to 800 Hz

Table SVF110-2

FSVF110-3

SVF201

Power Interrupt

400-1 115V RMS, 400 Hz nominal settings

0V for 50 msec

Table SVF201-2

FSVF201-400-1

360-1 115V RMS, 360 Hz nominal settings

0V for 50 msec

Table SVF201-2

FSVF201-360-1

600-1 115V RMS, 600 Hz nominal settings

0V for 50 msec

Table SVF201-2

FSVF201-600-1

800-1 115V RMS, 800 Hz nominal settings

0V for 50 msec

Table SVF201-2

FSVF201-800-1

SVF301

Abnormal Steady State Limits for Voltage and Frequency 100V to 125V RMS, 360Hz to 800 Hz Apply for 30 mins

FSVF301

SVF302

Abnormal Voltage Transients

400-1 400 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF302-2 A-G

FSVF302-400-1

400-2 400 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table SVF302-2 H-N

FSVF302-400-2

400-3 400 Hz, Combined Transient

45V RMS to 180V RMS

Table SVF302-2 O

FSVF302-400-3

360-1 360 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF302-2 A-G

FSVF302-360-1

360-2 360 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table SVF302-2 H-N

FSVF302-360-2

360-3 360 Hz, Combined Transient

45V RMS to 180V RMS

Table SVF302-2 O

FSVF302-360-3

600-1 600 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF302-2 A-G

FSVF302-600-1

600-2 600 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table SVF302-2 H-N

FSVF302-600-2

600-3 600 Hz, Combined Transient

45V RMS to 180V RMS

Table SVF302-2 O

FSVF302-600-3

800-1 800 Hz, Overvoltage Transients

Peak Voltage 180V RMS

Table SVF302-2 A-G

FSVF302-800-1

800-2 800 Hz, Undervoltage Transients

Low Voltage 45V RMS

Table SVF302-2 H-N

FSVF302-800-2

800-3 800 Hz, Combined Transient

45V RMS to 180V RMS

Table SVF302-2 O

FSVF302-800-3

SVF303

Abnormal Frequency Transients

1

Overfrequency Transients

High Frequency 800 Hz

Table SVF303-2 A-D

FSVF303-1

2

Underfrequency Transients

Low Frequency 360 Hz

Table SVF303-2 E-H

FSVF303-2

3

Combined Transient

360 Hz to 800 Hz

Table SVF303-2 I

FSVF303-3

SVF401

Emergency Limits for Voltage and Frequency

Perform Test SVF102

SVF501

No Tests

N/A to AC Utilization Equipment

SVF601

Power Failure (Single Phase)

400-1 115V RMS, 400 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-400-1

360-1 115V RMS, 360 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-360-1

600-1 115V RMS, 600 Hz nominal settings

0V for 7 seconds

Table SVF601-2

FSVF601-600-1