beautypg.com

Table zdc14 – AMETEK Compact i/iX Series Software Manual User Manual

Page 45

background image

User Manual - Rev H

California Instruments

Avionics Software

45

3.4.1.10 Table ZDC14:

Test No.

Section

Subject

Test Limits

Comment

File Ref.

16.6.1

Normal Operating Conditions (dc)

16.6.1.1b Voltage (Average Value dc)

11.0V to 15.2V

Apply for 30 mins each test

EZDC14_VAVG

16.6.1

Emergency Operating Conditions (dc)

16.6.1.1b(3) Voltage (Average Value dc)

9.0V

Apply for 30 mins each test

EZDC14_VAVGEMER

16.6.1

Normal Operating Conditions (dc)

16.6.1.2

1

Ripple Voltage (dc)

Vp-p = 0.3V to .8V, Freq = 10Hz to 200Hz Figure 18-2

EZDC14_VRIP

16.6.1.3b Momentary Power Interruptions (dc)

Table 16-3

Equipment with Digital Circuits

EZDC14_PINTB

16.6.1.3c Momentary Power Interruptions (dc)

Other Equipment

EZDC14_PINTC

16.6.1.4 Normal Transients (dc)

16.6.1.4b - Normal Voltage Surge (dc)

25V to 6V

EZDC14_NVSUR

16.6.1.5 Engine Starting Under Voltage Operation (dc) 5V min

Slew for 35 sec

EZDC14_VENG

16.6.2

Abnormal Operating Conditions (dc)

16.6.2.1 Voltage Steady State (dc)

10.3V to 16.1V

Apply for 5 mins each test

EZDC14_VABN

16.6.2.3 Momentary Undervoltage (dc)

6V

Apply for 7 seconds each test

EZDC14_VUND

16.6.2.4 Abnormal Transients (ac)

16.6.2.4b - Abnormal Voltage Surge

40VDC

Figure 16-4 - apply at 10 sec intervals EZDC14_AVSUR

1

For more comprehensive DC Ripple tests, refer to section 3.3.