beautypg.com

Option –amd: airbus amd-24 rev c tests, Test coverage, Mx series –amd option limitations – AMETEK Compact i/iX Series Software Manual User Manual

Page 186: Option, Amd: airbus amd-24 rev c tests, 8 option –amd: airbus amd-24 rev c tests, 1 test coverage

background image

User Manual

– Rev H

California Instruments

Avionics Software

186

8 Option

–AMD: Airbus AMD-24 Rev C Tests

The -AMD option supports Airbus AMD-24 rev C voltage and frequency immunity tests in both AC and
DC modes (if available).

The

–AMD option is based on Airbus A400M Directive: AMD-24 Issue C, Electrical characteristics of

aircraft AC and DC systems Appendix C dated March 22, 2005.

Future revisions of the AMD-24 directive may be issued over time and updates may be made
available to cover any changes in test levels, durations, procedures etc. Furthermore, the

–AMD

option is completely data file driven to allow a large degree of customization by the end-user if needed
so many changes can be supported without the need for software updates.

This section of the manual explains the limitations of this test option, the use of special features
unique to this option, and gives a complete layout of all tests performed by this option.

This manual is not intended to elaborate on the intent or purpose of the immunity tests and the
expected behavior of the EUT as described in the Airbus documents. It is assumed that the end-user
is familiar with the content of the AMD-24 test standard.

Note: All three phase California Instruments power sources have a phase rotation of A C B where
phase C is +120° from phase A and phase B is +240° from phase A. Some interpretations of this
specification call for phase B to be +120° from phase A. The easiest way to accomplish an ABC
phase rotation is to simply switch phase B and phase C wires at the EUT input. Alternatively, the
programmed phase angles for B and C can be changed but this will require editing of the test scripts
and is not recommended.

8.1 Test Coverage

The comprehensiveness of the tests that can be performed with the

–AMD option is determined

primarily by the capabilities of the power source used. Tests that are outside the hardware capabilities
of the power source used will not be enabled and cannot be selected. For these tests, additional
equipment may be required as indicated.

8.1.1

MX Series

–AMD Option Limitations

The extent of coverage of the

–AMD option as implemented on the MX Series platform is shown in

the table below. Tests marked with an „x‟ generally require additional hardware to be used. Tests
marked „N/A‟ are not applicable to the corresponding table. Tests marked with a „

‟ are covered by

the

–AMD tests. Tests marked with a „P‟ require arbitrary waveform capability, which is available on Pi

models or base models with the

–ADV option only. Additional implementation issues may apply as

well as indicated in section 8.1.1.1.

Furthermore, the MX Series does not meet the required 1.25% maximum Vthd over the 360 to 800Hz
frequency range required for the distorted voltage test per Appendix D.

Note: The MX15 Series power sources are single phase output only and therefore all three phase
tests are not available on the MX15.

No.

Description

Table

SVF

Table

TVF

Table

SCF

Table

TCF

No.

Description

Table

LDC

101

Steady State Voltage and
Frequency

101

Steady State Voltage

102

Voltage Transients

101-

APU

Steady State Voltage

103

Voltage Modulation

102

Voltage Transients