Table a(cf)115 – AMETEK Compact i/iX Series Software Manual User Manual
Page 54
User Manual
– Rev H
California Instruments
54
Avionics Software
3.4.2.10 Table A(CF)115:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b Voltage (Average Value dc)
11.0V to 15.2V
Apply for 30 mins each test
FZDC14_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3) Voltage (Average Value dc)
9.0V
Apply for 30 mins each test
FZDC14_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = 0.3V to .8V, Freq = 10Hz to 200Hz Figure 18-2
FZDC14_VRIP
16.6.1.3b Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
FZDC14_PINTB
16.6.1.3c Momentary Power Interruptions (dc)
Other Equipment
FZDC14_PINTC
16.6.1.4 Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
25V to 6V
FZDC14_NVSUR
16.6.1.5 Engine Starting Under Voltage Operation (dc) 5V min
Slew for 35 sec
FZDC14_VENG
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1 Voltage Steady State (dc)
10.3V to 16.1V
Apply for 5 mins each test
FZDC14_VABN
16.6.2.3 Momentary Undervoltage (dc)
6V
Apply for 7 seconds each test
FZDC14_VUND
16.6.2.4 Abnormal Transients (ac)
16.6.2.4b - Abnormal Voltage Surge
40VDC
Figure 16-4 - apply at 10 sec intervals FZDC14_AVSUR
1
For more comprehensive DC Ripple tests, refer to section 3.3.