Table b – AMETEK Compact i/iX Series Software Manual User Manual
Page 179
User Manual - Rev H
California Instruments
Avionics Software
179
7.4.2.2
Table B:
#
Test
No.
Subject
Test Limits
DO160 Ref.
Comments
Test File
1
16.5.1.1.b.1 test 1,2,3
Apply at 430Hz and 370Hz, Replace
100V & 122V with 23V & 28V
B1P0_NSSVF
2
2
Abnormal Steady State Voltage
21V to 30V RMS
16.5.3.1.b
Apply for 30 mins iso 5 mins
B2P0_ABN_SSV
3
3
4
3.1
Normal Transients
36.5V for 30ms, 16.1V
for 15ms
16.5.1.5.b
Use specified limit iso DO160
B3P0_NORMVSURGE1
5
3.2
Normal Transients
35.6V for 50ms, 18.2V
for 30ms
16.5.1.5.b
Use specified limit iso DO160
B3P0_NORMVSURGE2
6
3.3
Normal Transients
33.8V for 19.5ms, 86V
for 50ms
16.5.1.5.b
Use specified limit iso DO160
B3P0_NORMVSURGE3
7
3.4
Normal Transients
32V for 200ms
16.5.1.5.b
No undervoltage has to be applied
B3P0_NORMVSURGE4
8
4
Voltage Surge - Fig 1
9
4.1
Abnormal Transients
41.1V for 100ms, 33.8V
for 1 sec
16.5.3.3.1.b
B4P0_ABNVSURGE1
10
4.2
Abnormal Transients
0V for 5 secs
16.5.3.2.b
B4P0_ABNVSURGE2
11
4.3
Abnormal Transients
Disconnects for 5 secs
n/a
Appendix 3 tests
B4P3_APPENDIX3
12
5
Voltage Spike - Fig 3-B
Peak voltage 250V
17.4
Requires add'l equipment
13
6
Switching Transients
17.4
14
6.1
Appendix 1: Figure A
Table 1.1 - T1 = 10
msec
B6P0_APP1TransientsA
15
6.2.1
Appendix 1: Figure 1.B
Table 1.1 - N = 1
B6P0_APP1TransientsB_N1
16
6.2.2
Appendix 1: Figure 1.B
Table 1.1 - N = 2
B6P0_APP1TransientsB_N2
17
6.2.3
Appendix 1: Figure 1.B
Table 1.1 - N = 3
B6P0_APP1TransientsB_N3
18
6.2.4
Appendix 1: Figure 1.B
Table 1.1 - N = 4
B6P0_APP1TransientsB_N4
19
6.2.5
Appendix 1: Figure 1.B
Table 1.1 - N = 5
B6P0_APP1TransientsB_N5
20
6.2.6
Appendix 1: Figure 1.B
Table 1.1 - N = 6
B6P0_APP1TransientsB_N6
21
6.2.7
Table 1.1 - N = 7
B6P0_APP1TransientsB_N7
22
6.2.8
Appendix 1: Figure 1.B
Table 1.1 - N = 8
B6P0_APP1TransientsB_N8
23
6.2.9
Appendix 1: Figure 1.B
Table 1.1 - N = 9
B6P0_APP1TransientsB_N9
24
6.2.10
Appendix 1: Figure 1.B
Table 1.1 - N = 10
B6P0_APP1TransientsB_N1
0
25
6.2.11
Appendix 1: Figure 1.B
Table 1.1 - N = 11
B6P0_APP1TransientsB_N1
1