AMETEK Compact i/iX Series Software Manual User Manual
Page 128
User Manual
– Rev H
California Instruments
128
Avionics Software
Variable Frequency A350 Power Groups
– MX Series (Requires –HF option).
AC Power Groups
No.
Description
SVF
TVF
SVFH
TVFH
Normal Operation
101
Steady-state voltage and frequency
YES
YES
YES
YES
102
Voltage transients
YES
YES
YES (2)
YES (2)
103
Voltage modulation
YES
YES
YES
YES
104
Voltage spikes
X
X
X
X
105
Current distortion
YES
YES
YES
YES
106
Voltage distortion 1
P
P
P
P
107
Voltage distortion 2
X
X
X
X
108
Voltage distortion transients
P
P
P
P
109
Inrush current
YES
YES
YES
YES
110
Frequency variations
YES
YES
YES
YES
111
Frequency modulation
YES
YES
YES
YES
112
Voltage DC content
P
P
P
P
113
Voltage modulation due to equipment
YES
YES
YES
YES
114
Voltage spike due to equipment load switching
YES
YES
YES
YES
115
Voltage unbalance transient
N/A
YES
N/A
YES
Abnormal Operation
201
Steady-state voltage and frequency
YES
YES
YES
YES
202
Voltage transients
YES
YES
YES (2)
YES (2)
203
Voltage modulation
YES
YES
YES
YES
Emergency Operation
301
Steady-state voltage and frequency
YES
YES
YES
YES
302
Voltage distortion 1
YES
YES
YES
YES
303
Voltage distortion 2
YES
YES
YES
YES
304
Voltage distortion transients
YES
YES
YES
YES
305
Inrush current
YES
YES
YES
YES
306
Frequency variations
YES
YES
YES
YES
307
Voltage modulation due to equipment
YES
YES
YES
YES
Switching Transients
401
Transparency time
YES
YES
YES
YES
402
Voltage switching transients 1
(1)
(1)
(1)
(1)
403
Voltage switching transients 2
(1)
(1)
(1)
(1)
404
Voltage switching transients with frequency change
YES
YES
YES
YES
Power Supply Removal
501
Power line disconnection
YES
YES
YES
YES
Note (1): Provided through ABD Switching Transients test menu.
Note (2): Requires
–HV option.
Constant Frequency A350 Power Groups
– MX Series.